TX Operation
ATA5423/25/28/29 [Preliminary]
The transceiver is set to TX operation by using the bits OPM0 and OPM1 in the control
register 1.
Table 9-4.
Before activating TX mode, the TX parameters (baud rate, modulation scheme, etc.) must be
selected as illustrated in
in control register 6, Lim_min0 to Lim_min5 in control register 5 and XLIM in control register 4
(see section
control register 4. The FSK frequency deviation is fixed to about ±16 kHz. If P_Mode is set to
“1”, the Manchester modulator is disabled and pattern mode is active (NRZ, see
page
After the transceiver is set to TX mode, the start–up mode is active and the PLL is enabled. If the
PLL is locked, the TX mode is active.
If the transceiver is in start–up or TX mode, the TX/RX data buffer can be loaded via the 4–wire
serial interface. After the first byte is in the buffer and the TX mode is active, the transceiver
starts transmitting automatically (beginning with the MSB). While transmitting it is always possi-
ble to load new data in the TX/RX data buffer. To prevent a buffer overflow or interruptions
during transmitting, the user must ensure that data is loaded at the same speed as it is
transmitted.
There is a counter that indicates the number of bytes to be transmitted (see section
Configuration” on page
ted, the counter is decremented. The counter value is available via the 4–wire serial interface.
An IRQ is issued if the counter (while counting down) reaches the value defined by the control
bits IR0 and IR1 in control register 1.
Note:
If T_Mode in control register 1 is set to “1”, the transceiver is in TX transparent mode. In this
mode the TX/RX data buffer is disabled and the TX data stream must be applied on pin
SDI_TMDI.
64).
Writing to the control register 1, 4, 5 or 6 during TX mode resets the TX/RX data buffer and the
counter which indicates the number of bytes to be transmitted.
Figure 9-11 on page 63
OPM1
“Control Register” on page
Control Register 1
0
49). If a byte is loaded, the counter is incremented, if a byte is transmit-
Figure 9-11 on page
illustrates the flow chart of the TX transparent mode.
38). The modulation is selected with ASK/_NFSK in
OPM0
63. The baud rate depends on Baud 0 and Baud 1
1
Function
TX mode
4841A–RKE–02/05
Table 9-5 on
“Transceiver