ADT7473 Analog Devices, Inc., ADT7473 Datasheet - Page 66
ADT7473
Manufacturer Part Number
ADT7473
Description
Dbcool Remote Thermal Monitor And Fan Controller
Manufacturer
Analog Devices, Inc.
Datasheet
1.ADT7473.pdf
(76 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7473ADI
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7473ARQZ
Manufacturer:
ADI
Quantity:
297
Part Number:
ADT7473ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7473ARQZ-1R7
Manufacturer:
ON Semiconductor
Quantity:
500
Part Number:
ADT7473ARQZ-1R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7473ARQZ-1RL
Manufacturer:
ON Semiconductor
Quantity:
1 750
Part Number:
ADT7473ARQZ-1RL
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
ADT7473ARQZ-REEL
Manufacturer:
ON/安森美
Quantity:
20 000
ADT7473
Table 34. Register 0x5C, Register 0x5D, and Register 0x5E—Configuration Register
Bit
[2:0]
[3]
[4]
[7:5]
Table 35. TEM
R
0x5F
0x60
0x61
1
These registers become read-only when the Configuration Register 1 lock bit is set. Any further attempts to write to these registers have no effect.
egister Address
N me
SP
SLOW
INV
BHVR
P T
a
IN
RANGE
R/W
R/W
R/W
R/W
/PWM Frequency Registers
1
R/W
R/W
R/W
R/W
R/W
Description
Remote 1 T
Local temperature T
Remote 2 T
Description
These bits control the start-up timeout for PWMx. The PWM output stays high until two
valid TACH rising edges are seen from the fan. If there is not a valid TACH signal during the
fan TACH measurement directly after the fan start-up
mea
minimum high and low bytes contain 0xFFFF or 0x0000, then the Interrupt Status Register
2 bit is not set, ev
000 = No
001 = 10 0 ms.
010 = 250 ms (default).
011 = 40 0 ms.
100 = 66 7 ms.
101 = 1 s ec.
110 = 2 s ec.
111 = 4 sec.
SLOW = 1 makes the ramp rates for acoustic enhancement four times longer.
This bit inverts the PWM output. The default is 0, which corre
for 100% duty cycle. Setting this bit to 1 inverts t
corresponds to a logic low output.
These bits assign each fan to a particular temperature sensor for localized cooling.
000 = Remote 1 temperatur
001 = Local temperature controls PWM
010 = Remote 2 temperature controls PWMx (automatic fan control mode).
011 = PWMx runs full speed.
100 = PWMx disabled (de
101 = Fastest speed calculated by local a
110 = Fastest speed calculated by all three temperature channel controls PWMx.
111 = Manual mode. PWM duty cycle registers (Register 0x30 to Register 0x32) become
writable.
sure
RANGE
RANGE
ment reads 0xFFFF and In
start-up t
/PWM1 frequency.
/PWM3 frequency.
Rev. A | Page 66 of 76
RANGE
en if the fan has not star
imeout.
/PWM2 frequency.
fault).
e controls PWMx (automatic fan control mode).
terrupt Status Register 2 reflects the fan fault. If the TACH
x (automatic fan control mode).
s (Power-On Default = 0x82)
nd Remote 2 temperature controls PWMx.
ted.
he PWM output, so 100% duty cycle
timeout period, then the TACH
Power-On Default
0xCC
0xCC
0xCC
sponds to a logic high output