CLC031VEC National Semiconductor, CLC031VEC Datasheet - Page 8

IC DESERIAL/DESCRMBLR VID 64TQFP

CLC031VEC

Manufacturer Part Number
CLC031VEC
Description
IC DESERIAL/DESCRMBLR VID 64TQFP
Manufacturer
National Semiconductor
Type
Descrambler/Deserializerr
Datasheet

Specifications of CLC031VEC

Applications
SDTV/HDTV
Mounting Type
Surface Mount
Package / Case
64-TQFP, 64-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
*CLC031VEC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CLC031VEC
Manufacturer:
Texas Instruments
Quantity:
10 000
www.national.com
AC Electrical Characteristics
Note 3: Typical values are stated for V
Note 4: Spec. is guaranteed by design.
Note 5: Measured from rising-edge of first SDI cycle until Lock Detect bit goes high (true). Lock time includes CDR phase acquisition time plus PLL lock time.
Note 6: V
simultaneous output switching conditions. V
conditions.
Note 7: When used to clock control data into or from the CLC031, the duty cycle restriction does not apply.
Note 8: I
Note 9: Required Input Conditions are the electrical signal conditions or component values which shall be supplied by the circuit in which this device is used in order
for it to produce the specified DC and AC electrical output characteristics.
Note 10: Functional and certain other parametric tests utilize a CLC030 as the input source to the SDI inputs of the CLC031. The CLC030 is DC coupled to the
inputs of the CLC031. Typical V
Test Loads
IH
OHV
includes static current required by input pull-down devices.
and V
OLP
are measured with respect to reference ground. V
IN
= 800 mV, V
DDIO
OHV
= V
CM
DDSI
is the lowest output HIGH voltage or output droop that may occur under dynamic simultaneous output switching
= 2.9 V.
= +3.3V, V
(Continued)
DDD
= V
DDPLL
OLP
= +2.5V and T
is the peak output LOW voltage or ground bounce that may occur under dynamic
8
A
= +25˚C.
20020104