ATtiny2313A Atmel Corporation, ATtiny2313A Datasheet - Page 46

no-image

ATtiny2313A

Manufacturer Part Number
ATtiny2313A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny2313A

Flash (kbytes)
2 Kbytes
Pin Count
20
Max. Operating Frequency
20 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
18
Ext Interrupts
18
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
1
Uart
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
0.12
Eeprom (bytes)
128
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
4
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny2313A-MMH
Manufacturer:
SAMSUNG
Quantity:
101
Part Number:
ATtiny2313A-MU
Manufacturer:
ATMEL
Quantity:
313
Company:
Part Number:
ATtiny2313A-MU
Quantity:
20 000
Part Number:
ATtiny2313A-MUR
Manufacturer:
LT
Quantity:
4 439
Part Number:
ATtiny2313A-PU
Manufacturer:
TI
Quantity:
1 560
Part Number:
ATtiny2313A-PU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
ATtiny2313A-PU
Quantity:
1 800
Part Number:
ATtiny2313A-SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
46
ATtiny2313A/4313
the next time-out will generate a reset. To avoid the Watchdog Reset, WDIE must be set after
each interrupt.
Table 8-2.
• Bit 4 – WDCE: Watchdog Change Enable
This bit must be set when the WDE bit is written to logic zero. Otherwise, the Watchdog will not
be disabled. Once written to one, hardware will clear this bit after four clock cycles. See the
description of the WDE bit for a Watchdog disable procedure. This bit must also be set when
changing the prescaler bits. See
Watchdog Timer” on page
• Bit 3 – WDE: Watchdog Enable
When the WDE is written to logic one, the Watchdog Timer is enabled, and if the WDE is written
to logic zero, the Watchdog Timer function is disabled. WDE can only be cleared if the WDCE bit
has logic level one. To disable an enabled Watchdog Timer, the following procedure must be
followed:
In safety level 2, it is not possible to disable the Watchdog Timer, even with the algorithm
described above. See
Timer” on page
In safety level 1, WDE is overridden by WDRF in MCUSR. See
ter” on page 45
To clear WDE, WDRF must be cleared before disabling the Watchdog with the procedure
described above. This feature ensures multiple resets during conditions causing failure, and a
safe start-up after the failure.
Note:
1. In the same operation, write a logic one to WDCE and WDE. A logic one must be writ-
2. Within the next four clock cycles, write a logic 0 to WDE. This disables the Watchdog.
WDE
0
0
1
1
ten to WDE even though it is set to one before the disable operation starts.
If the watchdog timer is not going to be used in the application, it is important to go through a
watchdog disable procedure in the initialization of the device. If the Watchdog is accidentally
enabled, for example by a runaway pointer or brown-out condition, the device will be reset, which
in turn will lead to a new watchdog reset. To avoid this situation, the application software should
always clear the WDRF flag and the WDE control bit in the initialization routine.
Watchdog Timer Configuration
for description of WDRF. This means that WDE is always set when WDRF is set.
43.
WDIE
0
1
0
1
“Timed Sequences for Changing the Configuration of the Watchdog
Watchdog Timer State
Stopped
Running
Running
Running
43.
“Timed Sequences for Changing the Configuration of the
Action on Time-out
None
Interrupt
Reset
Interrupt
“MCUSR – MCU Status Regis-
8246B–AVR–09/11