Specifications of AT32UC3A0512AU

Flash (kbytes)
512 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
109
Ext Interrupts
109
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
1
Uart
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A0512AU-ALTRA
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A0512AU-ALUT
Manufacturer:
Atmel
Quantity:
10 000
32058K AVR32-01/12
13.6.11
BOD Level register
Register name
Register access
KEY: Register Write protection
FCD: BOD Fuse calibration done
CTRL: BOD Control
HYST: BOD Hysteresis
LEVEL: BOD Level
31
23
15
7
-
-
-
This field must be written twice, first with key value 0x55, then 0xAA, for a write operation to have an effect.
Set to 1 when CTRL, HYST and LEVEL fields has been updated by the Flash fuses after power-on reset or Flash fuses update
If one, the CTRL, HYST and LEVEL values will not be updated again by Flash fuses
Can be cleared to allow subsequent overwriting of the value by Flash fuses
0: BOD is off
1: BOD is enabled and can reset the chip
2: BOD is enabled and but cannot reset the chip. Only interrupt will be sent to interrupt controller, if enabled in the IMR register.
3: BOD is off
0: No hysteresis
1: Hysteresis On
This field sets the triggering threshold of the BOD. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD register should be done with the BOD deactivated to avoid spurious reset
or interrupt.
BOD Control
HYST
30
22
14
6
-
-
29
21
13
5
-
-
BOD
Read/Write
28
20
12
4
-
-
KEY
27
19
11
3
-
-
LEVEL
26
18
10
2
-
-
25
17
9
1
-
AT32UC3A
CTRL
FCD
24
16
8
0
81