AT32UC3A0512AU Atmel Corporation, AT32UC3A0512AU Datasheet - Page 747

no-image

AT32UC3A0512AU

Manufacturer Part Number
AT32UC3A0512AU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A0512AU

Flash (kbytes)
512 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
109
Ext Interrupts
109
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
1
Uart
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A0512AU-ALTRA
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A0512AU-ALUT
Manufacturer:
Atmel
Quantity:
10 000
32058K AVR32-01/12
36.6.4.2
36.6.5
Memory programming
Error reporting
What to do if the busy bit is set:
The Service access port may not be able to complete all accesses as requested. This may be
because the address is invalid, the addressed area is read-only or cannot handle byte/halfword
accesses, or because the chip is set in a protected mode where only limited accesses are
allowed.
The error bit is updated when an access completes, and is cleared when a new access starts.
What to do if the error bit is set:
The High-Speed Bus (HSB) in the device is mapped as a slave on the SAB. This enables all
HSB-mapped memories to be read or written through the SAB using JTAG instructions, as
described in
Internal SRAM can always be directly accessed. External static memory or SDRAM can be
accessed if the EBI has been correctly configured to access this memory. It is also possible to
access the configuration registers for these modules to set up the correct configuration. Simi-
larly, external parallel flash can be programmed by accessing the registers for the flash device
through the EBI.
The internal flash and fuses can likewise be programmed by accessing the registers in the Flash
Controller. When the security fuse is set, access to internal memory is blocked, and the
CHIP_ERASE instruction must be used to erase the fuse and flash contents. For detail see the
SAB address map section.
• A SYNC countdown completed.
• A operation is cancelled by the CANCEL_ACCESS instruction.
• During Shift-IR: The new instruction is selected, but the previous operation has not yet
• During Shift-DR of an address: The new address is ignored. The SAB stays in address mode,
• During Shift-DR of read data: The read data are invalid. The SAB stays in data mode. Repeat
• During Shift-DR of write data: The write data are ignored. The SAB stays in data mode.
• During Shift-IR: The new instruction is selected. The last operation performed using the old
• During Shift-DR of an address: The previous operation failed. The new address is accepted.
• During Shift-DR of read data: The read operation failed, and the read data are invalid.
• During Shift-DR of write data: The previous write operation failed. The new data are accepted
• While polling with CANCEL_ACCESS: The previous access was cancelled. It may or may not
completed and will continue (unless the new instruction is CANCEL_ACCESS). You may
continue shifting the same instruction until the busy bit clears, or start shifting data. If shifting
data, you must be prepared that the data shift may also report busy.
so no data must be shifted. Repeat the address until the busy bit clears.
scanning until the busy bit clears.
Repeat scanning until the busy bit clears.
instruction did not complete successfully.
If the read bit is set, a read operation is started.
and a write operation started. This should only occur during block writes or stream writes. No
error can occur between scanning a write address and the following write data.
have actually completed.
Section
36.6.4.
AT32UC3A
747

Related parts for AT32UC3A0512AU