PSB 21373 H V1.1 Infineon Technologies, PSB 21373 H V1.1 Datasheet - Page 63

no-image

PSB 21373 H V1.1

Manufacturer Part Number
PSB 21373 H V1.1
Description
IC SPEECH AND VOICE MQFP-44
Manufacturer
Infineon Technologies
Series
SCOUT™r
Datasheet

Specifications of PSB 21373 H V1.1

Function
CODEC
Interface
IOM-2, SCI
Number Of Circuits
1
Voltage - Supply
5V
Current - Supply
97.5mA
Mounting Type
Surface Mount
Package / Case
44-BQFP
Includes
Activation and Deactivation, Channel Handler, DTMF / Tone / Ringing Generator, HDLC Controller, Speakerphone, Voice Monitoring
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Operating Temperature
-
Other names
PSB21373HV1.1XT
PSB21373HV11XT
SP000007602
PSB 21373
The clock pulses will be enabled again when the DU line is pulled low (bit SPU in the
IOM_CR register) i.e. the C/I command TIM = "0000" is received by layer 1, or when a
non-zero level on the line interface is detected. The clocks are turned on after
approximately 0.2 to 4 ms depending on the capacitances on XTAL 1/2.
DCL is activated such that its first rising edge occurs with the beginning of the bit
following the C/I (C/I0) channel.
After the clocks have been enabled this is indicated by the PU code in the C/I channel
and by a CIC interrupt. The DU line may be released by resetting the Software Power
Up bit IOM_CR =’0’ and the C/I code written to CIX0 before (e.g. TIM or AR8) is output
on DU.
The SCOUT-DX supplies IOM timing signals as long as there is no DIU command in the
C/I (C/I0) channel. If timing signals are no longer required and activation is not yet
requested, this is indicated by programming DIU in the CIX0 register.
Data Sheet
63
2002-05-13

Related parts for PSB 21373 H V1.1