Specifications of PSB 21373 H V1.1

Function
CODEC
Interface
IOM-2, SCI
Number Of Circuits
1
Voltage - Supply
5V
Current - Supply
97.5mA
Mounting Type
Surface Mount
Package / Case
44-BQFP
Includes
Activation and Deactivation, Channel Handler, DTMF / Tone / Ringing Generator, HDLC Controller, Speakerphone, Voice Monitoring
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Operating Temperature
-
Other names
PSB21373HV1.1XT
PSB21373HV11XT
SP000007602
4.8.2
The codec registers (60
chapter 2.1 and 4.8.2.1).
4.8.2.1
For the direct access to individual CRAM coefficients via microcontroller a back-up
procedure is provided. This ensures that the codec DSP always works with a consistent
and valid coefficient block during the changing of CRAM parameters. The following
section describes this back-up procedure.
Note: For the ARCOFI compatible programming sequence (see chapter 2.1.1.1) such a
The control of the back-up procedure is done with the CRAM Control Register (CCR) and
the CRAM Status Register (CSR).The Control and Status bits in these registers are
explained in the following section:
CRAM Block Address (CBADR)
The CRAM range (80
CBADR =’0
coefficients corresponds to the COP_x sequences of the ARCOFI (see table 22 and
chapter 4.8.1.1).
DSP CRAM Access (DCA)
By setting this bit it is possible to select whether the codec DSP has access to the CRAM
blocks in the normal CRAM range (’0’) or to a temporary 8-byte CRAM block (’1’).
Start Back-up Procedure (SBP)
Setting this bit starts the transfer of a CRAM block (CBADR) to the temporary 8-byte
CRAM block.
Busy Back-up Procedure (BSYB)
This status bit indicates if a transfer of a CRAM block (CBADR) to the temporary 8-byte
CRAM block is running (’1’) or not (’0’). If the transfer is running no CRAM access via
microcontroller interface is allowed.
Figure 72 shows the access structure of CRAM and temporary CRAM. Figure • 73 gives
a signal flow of the back-up procedure of a CRAM block x (x = 0...F).
Data Sheet
back-up procedure for the CRAM blocks is not necessary because it is done
automatically.
Direct Programming of the Codec
CRAM Back-Up Procedure
H
’ to’F
H
’. Each coefficient block has 8 bytes. The mapping of the CRAM
H
to FF
H
-6F
H
H
) is subdivided in 16 CRAM blocks with the block address
) and the CRAM (80
146
H
-FF
H
) are directly accessible (see
PSB 21373