RC28F320J3F75A Micron Technology Inc, RC28F320J3F75A Datasheet - Page 50

no-image

RC28F320J3F75A

Manufacturer Part Number
RC28F320J3F75A
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of RC28F320J3F75A

Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RC28F320J3F75A
Manufacturer:
MIC
Quantity:
233
Part Number:
RC28F320J3F75A
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Figure 18: Byte/Word Program Flowchart
Datasheet
50
FULL STATUS CHECK PROCEDURE
Program Complete
Check if Desired
Write Data and
Register Data
(See Above)
Read Status
Read Status
Write 40H,
Successful
Full Status
Byte/Word
Byte/Word
Program
Address
Address
Register
SR.7 =
SR.3 =
SR.1 =
SR.4 =
Start
0
0
0
1
1
1
1
0
Voltage Range Error
Device Protect Error
Programming Error
Numonyx
®
Embedded Flash Memory (J3 65 nm) Single Bit per Cell (SBC)
1. Toggling OE# (low to high to low) updates the status register. This
can be done in place of issuing the Read Status Register command.
Repeat for subsequent programming operations.
SR full status check can be done after each program operation, or
after a sequence of programming operations.
Write FFH after the last program operation to place device in read
array mode.
Toggling OE# (low to high to low) updates the status register. This can
be done in place of issuing the Read Status Register command.
Repeat for subsequent programming operations.
SR.4, SR.3 and SR.1 are only cleared by the Clear Status Register
command in cases where multiple locations are programmed before
full status is checked.
If an error is detected, clear the status register before attempting retry
or other error recovery.
Operation
Operation
Standby
Standby
Standby
Standby
(Note 1)
Write
Write
Read
Bus
Bus
Word Program
Setup Byte/
Command
Command
Byte/Word
Program
Data = 40H
Addr = Location to Be Programmed
Data = Data to Be Programmed
Addr = Location to Be Programmed
Status Register Data
Check SR.7
1 = WSM Ready
0 = WSM Busy
Check SR.3
1 = Programming to Voltage Error
Check SR.1
1 = Device Protect Detect
Only required for systems
implemeting lock-bit configuration.
Check SR.4
1 = Programming Error
Detect
RP# = V
IH
Comments
Comments
, Block Lock-Bit Is Set
208032-03
Jan 2011

Related parts for RC28F320J3F75A