AT91SAM7X128 Atmel, AT91SAM7X128 Datasheet - Page 73

no-image

AT91SAM7X128

Manufacturer Part Number
AT91SAM7X128
Description
MCU 32-Bit 91S ARM7TDMI RISC 128KB Flash 1.8V/3.3V 100-Pin LQFP
Manufacturer
Atmel
Datasheet

Specifications of AT91SAM7X128

Package
100LQFP
Device Core
ARM7TDMI
Family Name
91S
Maximum Speed
55 MHz
Ram Size
32 KB
Program Memory Size
128 KB
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Program Memory Type
Flash
Number Of Programmable I/os
62
Interface Type
CAN/Ethernet/SPI/I2S/TWI/USART/USB
On-chip Adc
8-chx10-bit
Operating Temperature
-40 to 85 °C
Number Of Timers
3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X128-AU
Manufacturer:
ATMEL
Quantity:
1 045
Part Number:
AT91SAM7X128-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-AU-999
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-CU-999
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128B-AU
Manufacturer:
Atmel
Quantity:
1 929
Part Number:
AT91SAM7X128B-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128B-AU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
14. Real-time Timer (RTT)
14.1
14.2
Figure 14-1. Real-time Timer
14.3
6120H–ATARM–17-Feb-09
SLCK
RTT_MR
Overview
Block Diagram
Functional Description
RTTRST
reload
Divider
16-bit
RTT_MR
RTPRES
The Real-time Timer is built around a 32-bit counter and used to count elapsed seconds. It gen-
erates a periodic interrupt or/and triggers an alarm on a programmed value.
The Real-time Timer is used to count elapsed seconds. It is built around a 32-bit counter fed by
Slow Clock divided by a programmable 16-bit value. The value can be programmed in the field
RTPRES of the Real-time Mode Register (RTT_MR).
Programming RTPRES at 0x00008000 corresponds to feeding the real-time counter with a 1 Hz
signal (if the Slow Clock is 32.768 Hz). The 32-bit counter can count up to 2
sponding to more than 136 years, then roll over to 0.
The Real-time Timer can also be used as a free-running timer with a lower time-base. The best
accuracy is achieved by writing RTPRES to 3. Programming RTPRES to 1 or 2 is possible, but
may result in losing status events because the status register is cleared two Slow Clock cycles
after read. Thus if the RTT is configured to trigger an interrupt, the interrupt occurs during 2 Slow
Clock cycles after reading RTT_SR. To prevent several executions of the interrupt handler, the
interrupt must be disabled in the interrupt handler and re-enabled when the status register is
clear.
RTT_VR
RTT_AR
RTT_MR
RTTRST
0
1
Counter
CRTV
32-bit
ALMV
AT91SAM7X512/256/128 Preliminary
0
RTT_SR
RTT_SR
RTT_SR
=
read
reset
reset
set
set
RTTINC
ALMS
RTTINCIEN
RTT_MR
RTT_MR
ALMIEN
rtt_alarm
32
seconds, corre-
rtt_int
73

Related parts for AT91SAM7X128