U3402A-ABA AGILENT TECHNOLOGIES, U3402A-ABA Datasheet - Page 121

no-image

U3402A-ABA

Manufacturer Part Number
U3402A-ABA
Description
English Users And Service Guide 3400
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of U3402A-ABA

Rohs Compliant
NA
For Use With
U3400 Series U3402A Dual Display Multimeter
Table 6-11 Range and accuracy (±dB)
Rate
[1]
[2]
[3]
[4]
U3402A User’s and Service Guide
Slow
Medium
Fast
Autoranging is used when dBm operation is enabled.
In VAC 750 V range, 5% over-range is readable.
Reading displayed in dB when Rel operation is used.
For input voltage at frequency between 45 Hz to 1 kHz.
Voltage
range
120.000 mV
1.20000 V
12.0000 V
120.000 V
1000.00 VDC
750.00 VAC
400.00 mV
4.0000 V
40.000 V
400.00 V
1000.0 VDC
750.0 VAC
400.0 mV
4.000 V
40.00 V
400.0 V
1000 VDC
750 VAC
[1][2]
Decibel (dB) Calculation
Input voltage
6 mV to 120 mV
120 mV to 1.2 V
1.2 V to 12 V
12 V to 120 V
120 V to 1000 V
120 V to 750 V
20 mV to 400 mV
400 mV to 4 V
4 V to 40 V
40 V to 400 V
400 V to 1000 V
400 V to 750 V
20 mV to 400 mV
400 mV to 4 V
4 V to 40 V
40 V to 400 V
400 V to 1000 V
400 V to 750 V
dBm
600
–42.20 to –16.20
–16.20 to 3.80
3.80 to 23.80
23.80 to 43.80
43.80 to 62.22
43.80 to 59.72
–31.76 to –5.74
–5.74 to 14.26
14.26 to 34.26
34.26 to 54.26
54.26 to 62.22
54.26 to 59.72
–31.76 to –5.74
–5.74 to 14.26
14.26 to 34.26
34.26 to 54.26
54.26 to 62.22
54.26 to 59.72
[3]
ref
range at
20 Hz to 45 Hz 45 Hz to 10 kHz 10 kHz to 100 kHz
1.0
0.8
0.8
0.8
1.0
0.8
0.8
0.8
1.0
0.8
0.8
0.8
Specifications and Characteristics
Accuracy (One year; 23ºC ± 5ºC)
0.2
0.1
0.1
0.1
1.0
1.0
0.2
0.1
0.1
0.1
1.0
1.0
0.2
0.1
0.1
0.1
1.0
1.0
[4]
[4]
[4]
[4]
[4]
[4]
1.0
0.8
0.8
0.8
1.0
0.8
0.8
0.8
1.0
0.8
0.8
0.8
[1]
101
6