EZ80190AZ050EG Zilog, EZ80190AZ050EG Datasheet - Page 42

IC WEBSERVER 50MHZ XTEMP 100LQFP

EZ80190AZ050EG

Manufacturer Part Number
EZ80190AZ050EG
Description
IC WEBSERVER 50MHZ XTEMP 100LQFP
Manufacturer
Zilog
Datasheet

Specifications of EZ80190AZ050EG

Processor Type
eZ80
Features
High Speed, Single-Cycle Instruction-Fetch
Speed
50MHz
Voltage
3.3V
Mounting Type
Surface Mount
Package / Case
100-LQFP
Processor Series
EZ80190x
Core
eZ80
Data Bus Width
8 bit
Program Memory Type
ROMLess
Data Ram Size
8 KB
Interface Type
I2C, IrDA, SPI, UART
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
32
Number Of Timers
6
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-3865
EZ80190AZ050EG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80190AZ050EG
Manufacturer:
TYCO
Quantity:
120
Part Number:
EZ80190AZ050EG
Manufacturer:
Zilog
Quantity:
70
Part Number:
EZ80190AZ050EG
Manufacturer:
Zilog
Quantity:
10 000
Programmable Reload Timer Operation
PS006614-1208
PRT Clock
PRT Count
Value
(CLK/2)
IOWRN
Interrupt
Request
CLK
Setting Timer Duration
SINGLE PASS Mode
There are three factors to consider when determining Programmable Reload Timer dura-
tion—clock frequency, clock divider ratio, and initial count value. Minimum duration of
the timer is achieved by loading
edge. Maximum duration is achieved by loading
FFFFh
The time-out period of the PRT is returned by the following equation:
In SINGLE PASS mode, when the end-of-count value,
the timer is disabled, and the PRT_EN bit resets to 0. To restart the timer, the CPU must
reenable the timer by setting the PRT_EN bit to 1.
operating in SINGLE PASS mode. Timer register information is listed in
on page 33.
PRT Time-Out Period =
x
on the next clock edge and then continues counting down to
Figure 4. PRT SINGLE PASS Mode Operation Example
I/O Write to TMRx_CTL
4
Enables PRT
0001h
Clock Divider Ratio x Reload Value
3
System Clock Frequency
, because the timer times out on the next clock
2
0000h
Figure 4
0000h
, because the timer rolls over to
1
displays an example of a PRT
, is reached, counting halts,
Programmable Reload Timers
Product Specification
0000h
0
Table 3
.
eZ80190
32

Related parts for EZ80190AZ050EG