Specifications of EP1C20F324C7N

Number Of Logic Elements/cells
20060
Number Of Labs/clbs
2006
Total Ram Bits
294912
Number Of I /o
233
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
324-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-1678

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1C20F324C7N
Manufacturer:
ALTERA
Quantity:
784
Part Number:
EP1C20F324C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1C20F324C7N
Manufacturer:
ALTERA
0
Part Number:
EP1C20F324C7N
Manufacturer:
ALTERA
Quantity:
20 000
Altera Corporation
May 2008
migrating through different device densities. Dedicated row
interconnects route signals to and from LABs, PLLs, and M4K memory
blocks within the same row. These row resources include:
The direct link interconnect allows a LAB or M4K memory block to drive
into the local interconnect of its left and right neighbors. Only one side of
a PLL block interfaces with direct link and row interconnects. The direct
link interconnect provides fast communication between adjacent LABs
and/or blocks without using row interconnect resources.
The R4 interconnects span four LABs, or two LABs and one M4K RAM
block. These resources are used for fast row connections in a four-LAB
region. Every LAB has its own set of R4 interconnects to drive either left
or right.
interconnects can drive and be driven by M4K memory blocks, PLLs, and
row IOEs. For LAB interfacing, a primary LAB or LAB neighbor can drive
a given R4 interconnect. For R4 interconnects that drive to the right, the
primary LAB and right neighbor can drive on to the interconnect. For R4
interconnects that drive to the left, the primary LAB and its left neighbor
can drive on to the interconnect. R4 interconnects can drive other R4
interconnects to extend the range of LABs they can drive. R4
interconnects can also drive C4 interconnects for connections from one
row to another.
Direct link interconnects between LABs and adjacent blocks
R4 interconnects traversing four blocks to the right or left
Figure 2–9
shows R4 interconnect connections from a LAB. R4
MultiTrack Interconnect
Preliminary
2–13