System Configuration and Connection (Muting system)
Muting System
The muting function temporarily disables the safety function of the
F3SJ, keeping the control outputs ON even if beams are interrupted.
This makes it possible to install safety light curtains for AGV passage,
enabling both safety and productivity.
When muting, the muting lamp (external indicator) blinks to notify
people in the surrounding area that the safety functions are disabled.
For each operation modes, refer to page 73.
The muting and override functions disable the safety functions of the
device. Additional safety measures must be taken to ensure safety
while these functions are working.
Install muting sensors so that they can distinguish between the object
that is being allowed to be pass through the detection zone and a
person.
If the muting function is activated by the detection of a person, it may
result in serious injury.
Muting lamps (external indicators) that indicate the state of the muting
and override functions must be installed where they are clearly visible
to workers from all the operating positions.
Upgrading F3SJ for Muting System
1. Remove the caps of the emitter and receiver.
2. Install a muting lamp (external indicator) on either the emitter or
3. Attach the key cap for muting to the emitter/receiver on which the
(A screwdriver is included with the key cap for muting.)
receiver.
muting lamp (external indicator) was not installed.
2.
Cap
(Case: black)
External indicator set
Model F39-A01P@-PAC
1.
Muting lamp (external indicator)
!WARNING
Universal indicator
cable
Model F39-JJ3N
Brown: +, Blue: −
Commercially
available
external
indicator
3.
Key Cap for Muting
F39-CN6
(Case: orange)
1.
Cap
(Case: black)
Muting Sensor
A muting sensor is the sensor that is the trigger for temporarily
disabling the safety functions of F3SJ. You can use a through-beam
or retro-reflective photoelectric switch, a proximity sensor, or a limit
switch as the muting sensor. (OMRON's E3Z-series, E2E-series
(3-wire), E2VX-series, and D4N-series Sensors are recommended.)
For an F3SJ model with PNP output, use a sensor with a 3-wire PNP
transistor output or a NO contact output. For an F3SJ model with NPN
output, use a sensor with a 3-wire NPN transistor output or a NO
contact output.
Two-wire sensors cannot be used.
Muting Lamp (External indicator)
To notify workers that the muting function is working, external lamp(s)
must be installed. Use the F39-A01P@-PAC external indicator set or
an F39-JJ3N universal indicator cable with a commercially available
external indicator.
F3SJ Internal Indicators
Attachment Positions for Included Labels
Internal indicator labels are included with the F39-CN6 Key Cap for
Muting. When using a muting system, attach the internal indicator
labels so the arrows will be in line with the positions of the indicators,
as shown by the shading below.
• The muting input 1 indicator turns ON when input is applied to
• The muting input 2 indicator turns ON when input is applied to
• The muting input 1 indicator and muting input 2 indicator blink
• The muting error indicator on the receiver side turns ON when
muting input 1.
muting input 2.
under muting override.
there is a muting error.
Emitter