F3SJ-A0870P30 Omron, F3SJ-A0870P30 Datasheet - Page 57

no-image

F3SJ-A0870P30

Manufacturer Part Number
F3SJ-A0870P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 870 Mm Protected Height
Manufacturer
Omron
Datasheet
Wiring for connection with a controller G9SA-301-P (category 4) (NPN models only)
Timing Chart
E1
+24 VDC
0 V
G9SA-301-P
F39-JC@A-L
A1
Emergency stop switch
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
Emitter
A2
Interlock reset switch
External test switch
K1,K2 N.O. contact
*2. The output operation mode for auxiliary output 1 is
K1,K2 N.C. contact
Light interrupted
T11
PLC input 1 *2
PE
Control output
control output data/inverse of control output signals
enabled (default setting).
Light incident
a
PLC input 2
PLC output
T21
K1
K1
T12
(S1)
(S2)
(S3)
1
b
T23
K2
Communication
Communication
line (−) (Pink)
line (+) (Gray)
K2
T22
a
b
6
T31
A
Control
Circuit
K1
K2
B
T32
KM1
KM2
3
4
2
5
KM1
13
14
Receiver
F39-JC@A-D
23
24
12
11
KM2
33
34
22
21
41
42
JP
F3SJ settings
• Auto reset mode
• External device monitoring function disabled
G9SA-301-P settings
• Manual reset mode
• Using feedback loop
Using emergency stop switch
S3
1
2
3
4
5
6
IN1
PLC
*1
IN2
*1. If an emergency stop switch is not used, connect
S1:
S2:
S3:
S4:
KM1, KM2: Magnetic contactor
KM3:
M:
E1:
PLC:
OUT
control output 1 to T12 terminal and control
output 2 to T23 directly.
KM3
KM1
KM2
External test switch (connect to 24 V if the
switch is not necessary.)
Interlock reset switch
Emergency stop switch (direct opening
contacts) (A165E, A22E)
Lockout reset switch (connect to 0 V if the
switch is not necessary.)
Solid state contactor (G3J)
3-phase motor
24 VDC power supply (S82K)
Programmable controller
(Used for monitoring -- not related to safety
system)
Wiring for auto reset mode
M
T31
A
Control
Circuit
K1
K2
B
T32
KM1
KM2
F3SJ Ver.2
57