F3SJ-A0870P30 Omron, F3SJ-A0870P30 Datasheet - Page 16

no-image

F3SJ-A0870P30

Manufacturer Part Number
F3SJ-A0870P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 870 Mm Protected Height
Manufacturer
Omron
Datasheet
Item
Input voltage
Indicators
Mutual interference
prevention function
Series connection
Test functions
Safety functions
Model
PNP
output
NPN
output
Emitter
Receiver
outputs
outputs
PNP
NPN
Test input, interlock selection input, reset input, and muting input are all
ON voltage:9 to 24 V (Vs) (sink current: 3 mA max.)
OFF voltage:0 to 1.5 V, or open
External device monitoring input
ON voltage:9 to 24 V (Vs) (sink current: 5 mA max.)
OFF voltage:0 to 1.5 V, or open
Test input, interlock selection input, reset input, and muting input are all
ON voltage:0 to 1.5 V (short-circuit current 3 mA max.)
OFF voltage:9 to 24 V, or open
External device monitoring input
ON voltage:0 to 1.5 V (short-circuit current 5 mA max.)
OFF voltage:9 to 24 V, or open
Light intensity level indicators (green LED
Error mode indicators (red LED
Power indicator (green LED
Interlock indicator (yellow LED
External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED
ON/flash according to function
Light intensity level indicators (green LED
Error mode indicators (red LED
OFF output indicator (red LED
ON output indicator (green LED
ON/flash according to function
Interference light prevention algorithm, detection distance change function
Time division emission by series connection
F3SJ-A@@@@P14
F3SJ-A@@@@N14
Number of connections: up to 4 sets
Total number of beams: up to 400 beams
Maximum cable length for 2 sets: no longer than 15 m
Response time under connection: See page 20
Self test (when power is turned ON and while power is supplied)
External test (emission stop function by test input)
Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)
External device monitor
Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.)
Fixed blanking (must be set by a setting tool)
Floating blanking (must be set by a setting tool)
F3SJ-A@@@@P20
F3SJ-A@@@@N20
1): ON while power is on
1): ON while under interlock, blinks at lockout.
1): ON when safety output is OFF, blinks at lockout.
3): Blink to indicate error details
3): Blink to indicate error details
1): ON while safety output is ON muting error indicator, Blanking /test indicator (green LED
2, orange LED
2, orange LED
F3SJ-A@@@@N25
F3SJ-A@@@@P25
3): ON based on the light intensity
3): ON based on the light intensity
F3SJ-A@@@@P30
F3SJ-A@@@@N30
---
F3SJ Ver.2
F3SJ-A@@@@P55
F3SJ-A@@@@N55
2):
2):
16

Related parts for F3SJ-A0870P30