PN5120A0HN1/C1 NXP Semiconductors, PN5120A0HN1/C1 Datasheet - Page 103

no-image

PN5120A0HN1/C1

Manufacturer Part Number
PN5120A0HN1/C1
Description
RF Wireless Misc COMBO ANALOG/DIGI IC
Manufacturer
NXP Semiconductors
Type
Transmission Moduler
Datasheet

Specifications of PN5120A0HN1/C1

Package / Case
HVQFN EP
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 30 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PN5120A0HN1/C1,157

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PN5120A0HN1/C1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PN5120A0HN1/C1,118
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PN5120A0HN1/C1Ј¬118
Manufacturer:
NXP
Quantity:
6 000
Part Number:
PN5120A0HN1/C1Ј¬151
Manufacturer:
PH3
Quantity:
3 920
NXP Semiconductors
19. Testsignals
111334
Product data sheet
19.1 Selftest
19.2 Testbus
The PN512 has the capability to perform a digital selftest. To start the selftest the following
procedure has to be performed:
The testbus is implemented for production test purposes. The following configuration can
be used to improve the design of a system using the PN512. The testbus allows to route
internal signals to the digital interface. The testbus signals are selected by accessing
TestBusSel in register TestSel2Reg.
Table 155. Testsignal routing (TestSel2Reg = 07h)
Table 156. Description of Testsignals
Pins
D6
D5
D4
D3
D2
D1
D0
1. Perform a soft reset.
2. Clear the internal buffer by writing 25 bytes of 00h and perform the Config Command.
3. Enable the Selftest by writing the value 09h to the register AutoTestReg.
4. Write 00h to the FIFO.
5. Start the Selftest with the CalcCRC Command.
6. The Selftest will be performed.
7. When the Selftest is finished, the FIFO contains the following bytes:
Testsignal
Pins
– Correct answer for VersionReg equal to 80h:
0x00, 0xaa, 0xe3, 0x29, 0x0c, 0x10, 0x29, 0x6b
0x76, 0x8d, 0xaf, 0x4b, 0xa2, 0xda, 0x76, 0x99
0xc7, 0x5e, 0x24, 0x69, 0xd2, 0xba, 0xfa, 0xbc
0x3e, 0xda, 0x96, 0xb5, 0xf5, 0x94, 0xb0, 0x3a
0x4e, 0xc3, 0x9d, 0x94, 0x76, 0x4c, 0xea, 0x5e
0x38, 0x10, 0x8f, 0x2d, 0x21, 0x4b, 0x52, 0xbf
0xfb, 0xf4, 0x19, 0x94, 0x82, 0x5a, 0x72, 0x9d
0xba, 0x0d, 0x1f, 0x17, 0x56, 0x22, 0xb9, 0x08
Testsignal
sdata
scoll
svalid
sover
RCV_reset
RFon, filtered
Envelope
sdata
D6
Rev. 3.4 — 8 September 2009
Description
shows the actual received data stream.
shows if in the actual bit a collision has been detected (106 kbit only)
shows if sdata and scoll are valid
shows that the receiver has detected a stop condition
(ISO/IEC 14443A/ MIFARE mode only).
shows if the receiver is reset
shows the value of the internal RF level detector
shows the output of the internal coder
scoll
D5
svalid
D4
sover
D3
RCV_reset
D2
Transmission Module
filtered
RFon,
© NXP B.V. 2010. All rights reserved.
D1
PN512
Envelope
103 of 131
D0
PUBLIC

Related parts for PN5120A0HN1/C1