ISP1506BBS,557 NXP Semiconductors, ISP1506BBS,557 Datasheet - Page 28

RF Transceiver USB2.0 ULPI DDR OTG

ISP1506BBS,557

Manufacturer Part Number
ISP1506BBS,557
Description
RF Transceiver USB2.0 ULPI DDR OTG
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1506BBS,557

Operating Supply Voltage
1.65 V to 3.6 V
Mounting Style
SMD/SMT
Package / Case
HVQFN-24
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935278349557 ISP1506BBS
NXP Semiconductors
ISP1506A_ISP1506B_2
Product data sheet
Fig 9.
USE_EXT_VBUS_IND,
RXCMD A_VBUS_VLD indicator source
IND_PASSTHRU
9.5.2.3 Using and selecting the V
IND_COMPL
V
BUS
/FAULT
The V
link whenever there is a change in the V
must first enable the corresponding interrupts in the USB Interrupt Enable Rising Edge
and USB Interrupt Enable Falling Edge registers.
The link can use the V
shows the recommended usage for typical applications.
Table 14.
Standard USB host controllers:
500 mA on V
detect overcurrent conditions. If the external overcurrent detector provides a digital fault
signal, then the fault signal must be connected to the ISP1506 FAULT input pin, and the
link must do the following:
Standard USB peripheral controllers:
when V
start and end of USB peripheral operations. Detection of A_VBUS_VLD and SESS_END
thresholds is not needed for standard peripherals.
Application
Standard host
Standard peripheral no
OTG A-device
OTG B-device
1. Set the IND_COMPL bit in the Interface Control register to logic 0 or logic 1,
2. Set the USE_EXT_VBUS_IND bit in the OTG Control register to logic 1.
3. Set the IND_PASSTHRU bit in the Interface Control register to logic 1 (mandatory).
depending on the polarity of the external fault signal.
BUS
BUS
state encoding is shown in
V
A_VBUS_VLD comparator
is at a sufficient level for operation. SESS_VLD must be enabled to detect the
BUS
BUS
(V
indicators in RXCMD required for typical applications
BUS
in the range of 4.75 V to 5.25 V. An external circuit must be used to
< 4.4 V)
A_VBUS_VLD
yes
yes
no
Rev. 02 — 28 August 2008
BUS
internal A_VBUS_VLD
state to monitor V
BUS
state encoding
For standard hosts, the system must be able to provide
Table
BUS
Standard peripherals must be able to detect
SESS_VLD
no
yes
yes
yes
complement output
13. The ISP1506 will send an RXCMD to the
state. To receive V
BUS
ISP1506A; ISP1506B
and take appropriate action.
ULPI HS USB OTG transceiver
SESS_END
no
no
no
yes
(0, X)
(1, 1)
BUS
state updates, the link
© NXP B.V. 2008. All rights reserved.
RXCMD
A_VBUS_VLD
004aaa752
Table 14
27 of 79