CJ1W-EIP21 Omron, CJ1W-EIP21 Datasheet - Page 441

no-image

CJ1W-EIP21

Manufacturer Part Number
CJ1W-EIP21
Description
Ethernet I/P Module
Manufacturer
Omron
Datasheet

Specifications of CJ1W-EIP21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Precautions
All the above values are set to 0 if Ethernet communications functions are stopped due to improper settings in
the system setup.
These values are cleared when the EtherNet/IP Unit or built-in EtherNet/IP port is started or reset. Values will
be counted only until the maximum values are reached.
Response Codes
SOCKET STATUS READ
Reads the network socket status of the EtherNet/IP Unit or built-in EtherNet/IP port.
Command Block
Response Block
Parameters
Socket Status (Response)
Returns eight types of information in records of 32 bytes each. A maximum of 62 records can be returned. The
format of each record is shown below.
Protocol (4 bytes)
The protocol used for the socket is returned as a number.
00 00 00 06: TCP; 00 00 00 11: UDP
Receive Queue (4 bytes)
The number of bytes in the reception queue.
Send Queue (4 bytes)
The number of bytes in the send queue.
Local IP Address (4 bytes)
The local IP address allocated to the socket.
Local Port Number (4 bytes)
The local port number allocated to the socket.
Remote IP Address (4 bytes)
The remote IP address allocated to the socket.
FINS Commands Addressed to EtherNet/IP Units or Built-in EtherNet/IP Ports
0000
1001
Response code
Command
Command
27 64
27 64
code
code
Response
code
Normal end
Command too large
Socket status
32 bytes
Description
Socket status
32 bytes
Appendix E
413