Specifications of CDK5560

Number Of Adc's
1
Number Of Bits
24
Sampling Rate (per Second)
50k
Data Interface
Serial
Inputs Per Adc
1 Differential
Input Range
±3 V
Power (typ) @ Conditions
90mW @ 2.5 V
Voltage Supply Source
Dual ±
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
CS5560
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
598-1277
CDK5560-1
4.1.1
The Device sub-panel configures the CapturePlus II system to capture data from the evaluation board.
This sub-panel is always available.
Sub-panel Descriptions:
4.1.2
The Acquire sub-panel configures the software parameters for acquiring data sets from the evaluation
board. This sub-panel is always available. Click on the Acquire button to open this sub-panel.
Sub-panel Descriptions:
DS789UM2
– Pull-down menu: The pull-down menu selects the Cirrus Logic evaluation board and associated
– Load Config: Loads the ADC internal register configuration file. Information in the configuration
– Save Config: Saves the ADC internal register configuration file. The software makes a copy of the
– Number of Samples to Capture: Selects number of data samples to acquire. Note: Capturing
– Data Format: Displays the format of the data samples being acquired. The software automatically
device. In most cases, the software will read the evaluation board EEPROM and automatically
select the appropriate menu item.
file can be used to configure ADC internal registers. However, this function is not supported for all
Cirrus Logic ADCs.
ADC internal register configuration and saves it in the configuration file.
data sets is PC memory intensive. The PC requires sufficient memory to run the PC operating
system, CapturePlus II software, and to store captured data sets. Insufficient memory may limit the
ability to acquire larger data sets. A minimum of 1 gigabyte of RAM is recommended.
fills in the Data Format window based upon the evaluation board part number displayed in the
Device sub-panel. Change the data format between Bipolar and Unipolar by activating the adjacent
Up/Down buttons.
Device Sub-panel
Acquire Sub-panel
CapturePlus II