CDK5560 Cirrus Logic Inc, CDK5560 Datasheet - Page 34

KIT - CDB5560 W/ Capture Plus II System

CDK5560

Manufacturer Part Number
CDK5560
Description
KIT - CDB5560 W/ Capture Plus II System
Manufacturer
Cirrus Logic Inc
Series
CapturePLUS™IIr
Datasheets

Specifications of CDK5560

Number Of Adc's
1
Number Of Bits
24
Sampling Rate (per Second)
50k
Data Interface
Serial
Inputs Per Adc
1 Differential
Input Range
±3 V
Power (typ) @ Conditions
90mW @ 2.5 V
Voltage Supply Source
Dual ±
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
CS5560
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
598-1277
CDK5560-1
CapturePlus II
A.2.2
Measuring a Single Analog Input Signal
A test to determine the evaluation board performance with a full-scale input signal can be performed once
the hardware and software are configured. The following describes testing of the system using a typical
full-scale input signal.
Connect a 1 kHz, -0.5 dB signal into the evaluation board’s analog input channel.
Select the Frequency Domain window by clicking on the Frequency Domain tab at the top of the screen.
Deactivate the Grounded Input FFT. Activate the Log Freq Scale button. Several windowing functions are
available. In this example, the Window Type has been set to Crystal 7-Term.
34
DS789UM2

Related parts for CDK5560