Adding and Deleting PLCs
Note
When SYSMAC WAY (Host Link) Has Been Selected
The following Network Settings Dialog Box will be displayed as shown.
Setting the Network Tab Page
FINS Remote Address
This setting is required when going online with Position Control Unit mounted
on a PLC in the network. Use the default setting (Network: 0, Node: 0). For the
setting to go online with the PLC in the network, refer to 6-2-2 Connecting to
PLCs on Networks.
Frame Length
Use the default setting. When using 2 or more types of networks, use the
shorter frame length among them.
Response Timeout (s)
When timeouts occur in online operations, increase the value set for response
timeout (s).
Host Link Unit No.
Set the unit number of the Host Link port connected to the port on the com-
puter. When the unit number of the Host Link port has been changed, set the
applicable number.
• The response timeout can be set to between 1 s and 600 s. When a value
• Setting a response timeout shorter than 10 s may cause timeouts.
• Although the response timeout can be set to up to 600 s, online opera-
exceeding the range is set, it will be automatically adjusted so that it is
within the range.
tions (monitoring, device info, etc.) cannot be canceled once started.
Therefore, when setting a larger value for the response timeout, make
sure that it will not cause any problems even without operations from the
CX-Position.
Section 3-2
41