CQM1-CIF01 Omron, CQM1-CIF01 Datasheet - Page 124

no-image

CQM1-CIF01

Manufacturer Part Number
CQM1-CIF01
Description
PERIPHERAL CABLE FOR NEC COMP.
Manufacturer
Omron
Datasheet

Specifications of CQM1-CIF01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Position Control Unit Error Logs
Data Check at Startup
Data destruc-
tion
Common
parameters
Axis parame-
ters
Group
Parameters destruc-
tion
Data destruction
F-ROM check data
destruction
Operating data area
designation error
Operating data area
address designation
error
Parameter designa-
tion error
Axis designation
error
Response timeout
Name
The following table shows the errors checked when power is turned ON.
0001
0002
0003
0010
0011
0013
0014
0020
Code
When using the axis parameters in
the Position Control Unit, the
parameters saved in flash memory
are lost. It is possible that, while
saving to flash memory, the Posi-
tion Control Unit’s power supply
was interrupted, there was noise,
or there was an error in flash mem-
ory.
The following data saved in flash
memory will be lost:
Zones, positioning sequences,
speeds, acceleration/deceleration
data, positions, and dwell times.
It is possible that, while saving to
flash memory, the Position Control
Unit’s power supply was inter-
rupted, there was noise, or there
was an error in flash memory.
The flash memory error data
saved in flash memory is lost
(OMRON maintenance data is
lost).
It is possible that, while saving to
flash memory, the Position Control
Unit’s power supply was inter-
rupted, there was noise, or there
was an error in flash memory.
The operating data area designa-
tion (m) is incorrect.
• Area designation: Set to a setting
other than 00, 0D, or 0E.
• Bank designation: Set to a set-
ting not in the range 00 to 0C,
when 0E is set for the area desig-
nation.
The designation of the beginning
word of the operating data area’s
address (m+1) is outside the setta-
ble range.
The axis parameter designation
(m+2) is not set to 00 or 01.
The axis parameter designation
(m+2) is set to 01, but 1 is set for
an axis other than that for a 1-axis,
2-axis or 4-axis Unit.
The axis parameters set in the
CPU Unit could not be read to the
Position Control Unit.
Cause
In this condition, only the data
transfer (read and write) and data
save operations can be performed.
The Position Control Unit’s axis
parameters and data are all
returned to their default values.
After transferring the parameters
and data for all axes, save the
parameters and either reset the
power supply, or restart the Unit. If
the error persists, it is possible that
there is a fault in flash memory,
and so it may be necessary to
replace the Position Control Unit.
When this error occurs, operation
can be continued by performing
error reset. Execute the next oper-
ation after performing error reset.
In this condition, only the data
save operations can be performed.
All of the axes’ parameters and all
data will be returned to their
default values. After correcting the
common parameters, (refer to
SECTION 4), reset the power sup-
ply or restart the Position Control
Unit.
Increase the cycle monitor time set
with CX-Programmer and either
reset the power supply or restart
the Position Control Unit. If this
error occurs again, despite
increasing the cycle monitor time,
it is possible that there is a fault in
the Position Control Unit or some-
where in the PLC. Either replace
the whole PLC, or the Position
Control Unit.
Remedy
Section 11-1
103

Related parts for CQM1-CIF01