11730D AGILENT TECHNOLOGIES, 11730D Datasheet - Page 178

SENSOR CABLE, 50FT

11730D

Manufacturer Part Number
11730D
Description
SENSOR CABLE, 50FT
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 11730D

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Cable Length
50ft
Features
Reduces RFI Effect On Low Power Readings With Improved Shielding Design
Cable Assembly Type
Sensor
Cable Color
Gray
Rohs Compliant
No
For Use With
8480 & E-Series Power Sensors
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Agilent 85058B calibration kit, 1.85 mm
The Agilent 85058B calibration kit contains twelve standard devices
to characterize the systematic errors of Agilent network analyzers up
to 67 GHz for measurements of components with 1.85 mm
connectors. The standards allow one to perform simple 1- or 2-port
and thru-reflect-match (TRM) calibrations. This kit also contains
Electrical specifications
1
2
Typical performance.
This cal device is not used in this frequency range when your calibration is using a
polynomial model with Expanded Math unselected. Refer to “Two Models for
Defining Calibration Standards” (pages 1 – 2 of the 85058B/E Operation Manual).
Device
Lowband load
Open
Short 1
Short 2
Short 3
Short 4
Frequency (GHz)
DC to 10
10 to 20
20 to 35
35 to 60
60 to 67
DC to 10
10 to 35
35 to 50
50 to 67
DC to 20
20 to 30
30 to 35
35 to 40
40 to 50
50 to 67
DC to 20
20 to 30
30 to 35
35 to 40
40 to 50
50 to 67
DC to 20
20 to 30
30 to 35
35 to 40
40 to 50
50 to 67
DC to 20
20 to 30
30 to 35
35 to 40
40 to 50
50 to 67
1
1
Network Analyzer Accessories and Cal Kits
Parameter
Return loss
Deviation from
nominal phase
Deviation from
nominal phase
Deviation from
nominal phase
Deviation from
nominal phase
Deviation from
nominal phase
adapters and a torque wrench for proper connection. Each calibration
kit includes two models for defining calibration standards; the
data-based model (85058B), and the polynomial model (85058BP).
The data-based model provides a higher accuracy method for
describing calibration standards than the polynomial model.
Coaxial Mechanical Calibration Kits (continued)
www.agilent.com/find/mta
Polynomial
model
36 dB
34 dB
31 dB
22 dB
19 dB
2.2°
3.2°
N/A
N/A
1.7°
2.2°
2.2°
N/A
N/A
N/A
N/A
N/A
N/A
2.4°
2.6°
3.6°
N/A
N/A
N/A
2.4°
2.6°
4.4°
N/A
N/A
N/A
2.7°
3.1°
4.2°
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Male
Data-based Polynomial
model
36 dB
34 dB
31 dB
22 dB
19 dB
2.0°
3.0°
3.0°
4.5°
1.5°
2.0°
2.0°
2.0°
2.0°
3.0°
1.5°
2.0°
2.0°
2.0°
2.0°
3.0°
1.5°
2.0°
2.0°
2.0°
2.0°
3.0°
1.5°
2.0°
2.0°
2.0°
2.0°
3.0°
Specifications
model
35 dB
34 dB
29 dB
12 dB
10 dB
2.7°
3.7°
N/A
N/A
1.7°
2.2°
2.7°
N/A
N/A
N/A
N/A
N/A
N/A
2.9°
4.1°
4.6°
N/A
N/A
N/A
2.9°
4.1°
5.4°
N/A
N/A
N/A
2.9°
4.6°
5.2°
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Female
Data-based
model
35 dB
34 dB
29 dB
12 dB
10 dB
2.5°
3.5°
3.5°
5.0°
1.5°
2.0°
2.5°
2.5°
3.5°
4.0°
1.5°
2.0°
2.5°
2.5°
3.5°
4.0°
1.5°
2.0°
2.5°
2.5°
3.5°
4.0°
1.5°
2.0°
2.5°
2.5°
3.5°
4.0°
167
19

Related parts for 11730D