SENSOR CABLE, 50FT

11730D

Manufacturer Part Number
11730D
Description
SENSOR CABLE, 50FT
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 11730D

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Cable Length
50ft
Features
Reduces RFI Effect On Low Power Readings With Improved Shielding Design
Cable Assembly Type
Sensor
Cable Color
Gray
Rohs Compliant
No
For Use With
8480 & E-Series Power Sensors
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Specifications
Features
• Preselected mixers to eliminate signal identification
• State-of-the-art technology
• Easier automated measurements
• Low conversion loss
• Individually amplitude calibrated
• No bias or tuning adjustments
• High 100 mW safe input level
Compatibility
The Agilent 11970 series mixers extend the frequency range of the
Agilent E4440A/46A/48A PSA series high-performance spectrum
analyzers, E4407B ESA and 856xEC/E portable spectrum analyzers
up to 110 GHz. The Agilent 11970 series mixers are also
compatible with the Agilent 8566B spectrum analyzer (used with
the Agilent 11975A amplifier); and the Agilent 70000 modular
measurement system (used with the Agilent 70907A, B external
mixer interface module, or the Agilent 70909A and 70910A
RF sections).
Agilent 11970 and 11974 series specifications
IF range: DC to 1.3 GHz
LO amplitude range: +14 to +16 dB; +16 optimum
Calibration accuracy: ±2.0 dB for Agilent 11970
series with optimum LO amplitude
Typical RF input SWR: <2.2:1, <3.0:1 for Agilent 11974 series
Bias requirements: none
Typical odd-order harmonic suppression:
>20 dB (does not apply to Agilent 11974 series)
Maximum CW RF input level: +20 dBm
(100 mW), +25 dBm for Agilent 11974 series
Maximum peak pulse power: 24 dBm (250 mW)
with <1 µs pulse (avg. power = +20 dBm)
1
2
Frequency of the mixers is reduced by 1 dB with LO input power of 14.5 to 16.0 dBm.
Typical characteristic.
Agilent
model
11970K
11970A
11970Q
11970U
11970V
11970W
Frequency
range (GHz)
18 to 26.5
26.5 to 40
33 to 50
40 to 60
50 to 75
75 to 110
LO harmonic
number
6+
8+
10+
10+
14+
18+
Maximum
conversion
loss (dB)
24
26
28
28
40
47
Bandwidth: 100 MHz minimum (Agilent 11974 series only)
Environmental: Meets MIL-T-28800C, Type III, Class 3, Style C
IF/LO connectors: SMA female
Tune IN connector: BNC
LO range: 3.0 to 6.1 GHz
Ordering information
Agilent 11974A: 26.5 to 40 GHz preselected mixer
Agilent 11974Q: 33 to 50 GHz preselected mixer
Agilent 11974U: 40 to 60 GHz preselected mixer
Agilent 11974V: 50 to 75 GHz preselected mixer
Agilent 11970K: 18 to 26.5 GHz mixer
Agilent 11970A: 26.5 to 40 GHz mixer
Agilent 11970Q: 33 to 50 GHz mixer
Agilent 11970U: 40 to 60 GHz mixers
Agilent 11970V: 50 to 75 GHz mixers
Agilent 11970W: 75 to 110 GHz mixers
Agilent 11970
Agilent 11975A: 2 to 8 GHz amplifier
Agilent 281A, B: Coaxial to waveguide adapters
R281A: 26.5 to 40 GHz, 2.4 mm (f)
R281B: 26.5 to 40 GHz, 2.4 mm (m)
Q281A: 33 to 50 GHz, 2.4 mm (f)
Q281B: 33 to 50 GHz, 2.4 mm (m)
U281A: 40 to 60 GHz, 1.85 mm (f)
U281B: 40 to 60 GHz, 1.85 mm (m)
V281A: 50 to 64 GHz, 1.85 mm (f)
V281B: 50 to 64 GHz, 1.85 mm (m)
Option 003: Delete power supply
(Agilent 11974 series only)
Option 009: Mixer connection set adds three-1 meter
low-loss SMA cables, wrench, allen driver for any
Agilent 11970 series mixer. Carrying case with storage
space for cables and tools included.
Noise level (dB)
1 kHz RBW
–105
–102
–101
–101
–92
–85
www.agilent.com/find/mta
Frequency
response (dB)
±1.9
±1.9
±1.9
±1.9
±2.1
±3.0
1
Mixers (continued)
1 dB Gain
compression
(dBm)
–3
–5
–7
–7
–3
–1
Mixers
2
141
18

Related parts for 11730D