CS5102A-BL Cirrus Logic Inc, CS5102A-BL Datasheet - Page 35

A/D Converter (A-D) IC

CS5102A-BL

Manufacturer Part Number
CS5102A-BL
Description
A/D Converter (A-D) IC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CS5102A-BL

Input Channels Per Adc
2
Mounting Type
Surface Mount
No. Of Channels
2
Power Rating
44mW
Supply Voltage Min
4.5V
Peak Reflow Compatible (260 C)
No
Sample Rate
20kSPS
Supply Voltage Max
5.5V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5102A-BL
Manufacturer:
TI
Quantity:
4
Part Number:
CS5102A-BL
Manufacturer:
CRYSTAL
Quantity:
20 000
Part Number:
CS5102A-BLZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS5102A-BLZ
Manufacturer:
CRYSTAL
Quantity:
20 000
PARAMETER DEFINITIONS
Linearity Error
Differential Linearity
Full Scale Error
Unipolar Offset
Bipolar Offset
Bipolar Negative Full-Scale Error
Signal to Peak Harmonic or Noise
Total Harmonic Distortion
Signal-to-(Noise + Distortion)
Aperture Time
Aperture Jitter
The range of variation in the aperture time. Effectively the "sampling window" which ultimately dic-
tates the maximum input signal slew rate acceptable for a given accuracy. Units in picoseconds.
DS45F2
The deviation of a code from a straight line passing through the endpoints of the transfer
function after zero- and full-scale errors have been accounted for. "Zero-scale" is a point 1/2
LSB below the first code transition and "full-scale" is a point 1/2 LSB beyond the code
transition to all ones. The deviation is measured from the middle of each particular code. Units
in % Full-Scale.
Minimum resolution for which no missing codes is guaranteed. Units in bits.
The deviation of the last code transition from the ideal (VREF-3/2 LSB’s). Units in LSB’s.
The deviation of the first code transition from the ideal (1/2 LSB above AGND) when in
unipolar mode (BP/UP low). Units in LSB’s.
The deviation of the mid-scale transition (011...111 to 100...000) from the ideal (1/2 LSB below
AGND) when in bipolar mode (BP/UP high). Units in LSB’s.
The deviation of the first code transition from the ideal when in bipolar mode (BP/UP high).
The ideal is defined as lying on a straight line which passes through the final and mid-scale
code transitions. Units in LSB’s.
The ratio of the rms value of the signal to the rms value of the next largest spectral component
below the Nyquist rate (excepting dc). This component is often an aliased harmonic when the
signal frequency is a significant proportion of the sampling rate. Expressed in decibels.
The ratio of the rms sum of all harmonics to the rms value of the signal. Units in percent.
The ratio of the rms value of the signal to the rms sum of all other spectral components below
the Nyquist rate (excepting dc), including distortion components. Expressed in decibels.
The time required after the hold command for the sampling switch to open fully. Effectively a
sampling delay which can be nulled by advancing the sampling signal. Units in nanoseconds.
CS5101A CS5102A
35