Z8F0413HH005EG Zilog, Z8F0413HH005EG Datasheet - Page 79

IC ENCORE MCU FLASH 4K 20SSOP

Z8F0413HH005EG

Manufacturer Part Number
Z8F0413HH005EG
Description
IC ENCORE MCU FLASH 4K 20SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F0413HH005EG

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
20-SSOP
For Use With
770-1002 - ISP 4PORT ZILOG Z8 ENCORE! MCU269-4643 - KIT DEV Z8 ENCORE XP 28-PIN269-4630 - DEV KIT FOR Z8 ENCORE 8K/4K269-4629 - KIT DEV Z8 ENCORE XP 28-PIN269-4628 - KIT DEV Z8 ENCORE XP 8-PIN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Other names
269-4108
Z8F0413HH005EG
PS024314-0308
6. Write to the Timer Control register to enable the timer and initiate counting.
In ONE-SHOT mode, the system clock always provides the timer input. The timer period
is given by the following equation:
CONTINUOUS Mode
In CONTINUOUS mode, the timer counts up to the 16-bit Reload value stored in the
Timer Reload High and Low Byte registers. The timer input is the system clock. Upon
reaching the Reload value, the timer generates an interrupt, the count value in the Timer
High and Low Byte registers is reset to
Output alternate function is enabled, the Timer Output pin changes state (from Low to
High or from High to Low) at timer Reload.
Follow the steps below to configure a timer for CONTINUOUS mode and to initiate the
count:
1. Write to the Timer Control register to:
2. Write to the Timer High and Low Byte registers to set the starting count value (usually
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. Enable the timer interrupt (if appropriate) and set the timer interrupt priority by
5. Configure the associated GPIO port pin (if using the Timer Output function) for the
6. Write to the Timer Control register to enable the timer and initiate counting.
In CONTINUOUS mode, the system clock always provides the timer input. The timer
period is given by the following equation:
If an initial starting value other than
registers, use the ONE-SHOT mode equation to determine the first time-out period.
0001H). This action only affects the first pass in CONTINUOUS mode. After the first
timer Reload in CONTINUOUS mode, counting always begins at the reset value of
0001H
writing to the relevant interrupt registers.
Timer Output alternate function.
ONE-SHOT Mode Time-Out Period (s)
CONTINUOUS Mode Time-Out Period (s)
Disable the timer
Configure the timer for CONTINUOUS mode
Set the prescale value
If using the Timer Output alternate function, set the initial output level (High or
Low)
.
0001H
0001H
is loaded into the Timer High and Low Byte
=
and counting resumes. Also, if the Timer
(
---------------------------------------------------------------------------------------------- -
=
Reload Value Start Value
----------------------------------------------------------------------- -
System Clock Frequency (Hz)
System Clock Frequency (Hz)
Reload Value Prescale
Z8 Encore! XP
Product Specification
×
®
F0823 Series
) Prescale
×
Timers
69