Specifications of Z8F0413HH005EG

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
20-SSOP
For Use With
770-1002 - ISP 4PORT ZILOG Z8 ENCORE! MCU269-4643 - KIT DEV Z8 ENCORE XP 28-PIN269-4630 - DEV KIT FOR Z8 ENCORE 8K/4K269-4629 - KIT DEV Z8 ENCORE XP 28-PIN269-4628 - KIT DEV Z8 ENCORE XP 8-PIN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Other names
269-4108
Z8F0413HH005EG
HALT Mode
Peripheral-Level Power Control
Power Control Register Definitions
PS024314-0308
Executing the eZ8 CPU’s
powers down the CPU but leaves all other peripherals active. In HALT mode, the
operating characteristics are:
The eZ8 CPU can be brought out of HALT mode by any of the following operations:
To minimize current in HALT mode, all GPIO pins that are configured as inputs must be
driven to one of the supply rails (V
In addition to the STOP and HALT modes, it is possible to disable each peripheral on each
of the Z8 Encore! XP F0823 Series devices. Disabling a given peripheral minimizes its
power consumption.
The following sections describe the power control registers.
Power Control Register 0
Each bit of the following registers disables a peripheral block, either by gating its system
clock input or by removing power from the block.
Primary oscillator is enabled and continues to operate.
System clock is enabled and continues to operate.
eZ8 CPU is stopped.
Program counter stops incrementing.
Watchdog Timer’s internal RC oscillator continues to operate.
If enabled, the Watchdog Timer continues to operate.
All other on-chip peripherals continue to operate.
Interrupt
Watchdog Timer time-out (interrupt or reset)
Power-On Reset
Voltage Brownout reset
External RESET pin assertion
HALT
instruction places the device into HALT mode, which
CC
or GND).
Z8 Encore! XP
Product Specification
®
Low-Power Modes
F0823 Series
32