AT32UC3C0512CAU Atmel Corporation, AT32UC3C0512CAU Datasheet - Page 593

no-image

AT32UC3C0512CAU

Manufacturer Part Number
AT32UC3C0512CAU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3C0512CAU

Flash (kbytes)
512 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
123
Ext Interrupts
144
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
7
Twi (i2c)
3
Uart
5
Can
2
Lin
5
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
4
Dac Resolution (bits)
12
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
68
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6 or 4.5 to 5.5
Operating Voltage (vcc)
3.0 to 3.6 or 4.5 to 5.5
Fpu
Yes
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
22
Input Capture Channels
12
Pwm Channels
20
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3C0512CAU-ALUT
Manufacturer:
Atmel
Quantity:
10 000
25.6.5.3
Figure 25-34. IrDA Demodulator Operations
32117C–AVR-08/11
CLK_USART
Receiver
Counter
Value
Input
RXD
IrDA Demodulator
6
5
4
Rejected
Table 25-11. IrDA Baud Rate Error (Continued)
The demodulator is based on the IrDA Receive filter comprised of an 8-bit down counter which is
loaded with the value programmed in IFR. When a falling edge is detected on the RXD pin, the
Filter Counter starts counting down at the CLK_USART speed. If a rising edge is detected on the
RXD pin, the counter stops and is reloaded with IFR. If no rising edge is detected when the
counter reaches 0, the input of the receiver is driven low during one bit time.
Figure 25-34
As the IrDA mode uses the same logic as the ISO7816, note that the FI_DI_RATIO field in FIDI
must be set to a value higher than 0 in order to assure IrDA communications operate correctly.
Pulse
Peripheral Clock
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
3
2
6
illustrates the operations of the IrDA demodulator.
6
5
Baud Rate
4
38 400
38 400
19 200
19 200
19 200
19 200
9 600
9 600
9 600
9 600
2 400
2 400
2 400
3
2
1
0
Accepted
Pulse
107
130
130
213
260
521
853
CD
53
65
12
65
24
96
Driven Low During 16 Baud Rate Clock Cycles
Baud Rate Error
0.63%
0.16%
0.00%
0.16%
0.31%
0.16%
0.00%
0.16%
0.16%
0.16%
0.00%
0.03%
0.04%
AT32UC3C
Pulse Time
19.53
19.53
19.53
19.53
78.13
78.13
78.13
4.88
4.88
9.77
9.77
9.77
9.77
593