AD7792BRUZ Analog Devices Inc, AD7792BRUZ Datasheet - Page 23

no-image

AD7792BRUZ

Manufacturer Part Number
AD7792BRUZ
Description
IC ADC 16BIT SIG-DEL 3CH 16TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7792BRUZ

Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
16
Sampling Rate (per Second)
500
Number Of Converters
1
Power Dissipation (max)
2.5mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
16bit
Sampling Rate
470SPS
Input Channel Type
Differential
Supply Voltage Range - Analog
2.7V To 5.25V
Supply Voltage Range - Digital
2.7V To 5.25V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7792EBZ - BOARD EVALUATION FOR AD7792
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7792BRUZ
Manufacturer:
ADI
Quantity:
9
Part Number:
AD7792BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7792BRUZ-REEL
Manufacturer:
PERK
Quantity:
101
Part Number:
AD7792BRUZ-REEL
Manufacturer:
ADI原装
Quantity:
20 000
Company:
Part Number:
AD7792BRUZ-REEL
Quantity:
2 500
Company:
Part Number:
AD7792BRUZ-REEL
Quantity:
2 500
DOUT/RDY
Continuous Read
Rather than write to the communications register each time a
conversion is complete to access the data, the AD7792/AD7793
can be configured so that the conversions are placed on the
DOUT/ RDY line automatically. By writing 01011100 to the
communications register, the user needs only to apply the
appropriate number of SCLK cycles to the ADC, and the 16/24-
bit word is automatically placed on the DOUT/ RDY line when a
conversion is complete. The ADC should be configured for
continuous conversion mode.
When DOUT/ RDY goes low to indicate the end of a conver-
sion, sufficient SCLK cycles must be applied to the ADC, and
the data conversion is placed on the DOUT/ RDY line. When
the conversion is read, DOUT/ RDY returns high until the next
conversion is available. In this mode, the data can be read only
once. In addition, the user must ensure that the data-word is
SCLK
DIN
CS
0x5C
Figure 19. Continuous Read
Rev. B | Page 23 of 32
DATA
read before the next conversion is complete. If the user has not
read the conversion before the completion of the next
conversion, or if insufficient serial clocks are applied to the
AD7792/AD7793 to read the word, the serial output register is
reset when the next conversion is completed, and the new
conversion is placed in the output serial register.
To exit the continuous read mode, the instruction 01011000
must be written to the communications register while the
DOUT/ RDY pin is low. While in the continuous read mode, the
ADC monitors activity on the DIN line so that it can receive the
instruction to exit the continuous read mode. Additionally, a
reset occurs if 32 consecutive 1s are seen on DIN. Therefore,
DIN should be held low in continuous read mode until an
instruction is written to the device.
DATA
AD7792/AD7793
DATA

Related parts for AD7792BRUZ