AD7792BRUZ Analog Devices Inc, AD7792BRUZ Datasheet - Page 22

no-image

AD7792BRUZ

Manufacturer Part Number
AD7792BRUZ
Description
IC ADC 16BIT SIG-DEL 3CH 16TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7792BRUZ

Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
16
Sampling Rate (per Second)
500
Number Of Converters
1
Power Dissipation (max)
2.5mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP (0.173", 4.40mm Width)
Resolution (bits)
16bit
Sampling Rate
470SPS
Input Channel Type
Differential
Supply Voltage Range - Analog
2.7V To 5.25V
Supply Voltage Range - Digital
2.7V To 5.25V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-AD7792EBZ - BOARD EVALUATION FOR AD7792
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7792BRUZ
Manufacturer:
ADI
Quantity:
9
Part Number:
AD7792BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7792BRUZ-REEL
Manufacturer:
PERK
Quantity:
101
Part Number:
AD7792BRUZ-REEL
Manufacturer:
ADI原装
Quantity:
20 000
Company:
Part Number:
AD7792BRUZ-REEL
Quantity:
2 500
Company:
Part Number:
AD7792BRUZ-REEL
Quantity:
2 500
AD7792/AD7793
Single Conversion Mode
In single conversion mode, the AD7792/AD7793 are placed in
shutdown mode between conversions. When a single conver-
sion is initiated by setting MD2, MD1, MD0 to 0, 0, 1 in the
mode register, the AD7792/AD7793 power up, perform a single
conversion, and then return to shutdown mode. The on-chip
oscillator requires 1 ms to power up. A conversion requires a
time period of 2 × t
completion of a conversion. When the data-word has been read
from the data register, DOUT/ RDY goes high. If CS is low,
DOUT/ RDY remains high until another conversion is initiated
and completed. The data register can be read several times, if
required, even when DOUT/ RDY has gone high.
DOUT/RDY
DOUT/RDY
SCLK
SCLK
DIN
DIN
CS
CS
ADC
. DOUT/ RDY goes low to indicate the
0x08
0x200A
Figure 18. Continuous Conversion
0x58
Figure 17. Single Conversion
Rev. B | Page 22 of 32
DATA
Continuous Conversion Mode
This is the default power-up mode. The AD7792/AD7793
continuously converts, the RDY pin in the status register going
low each time a conversion is completed. If CS is low, the
DOUT/ RDY line also goes low when a conversion is complete.
To read a conversion, the user writes to the communications
register indicating that the next operation is a read of the data
register. The digital conversion is placed on the DOUT/ RDY
pin as soon as SCLK pulses are applied to the ADC.
DOUT/ RDY returns high when the conversion is read. The
user can read this register additional times, if required.
However, the user must ensure that the data register is not being
accessed at the completion of the next conversion, otherwise the
new conversion word is lost.
0x58
0x58
DATA
DATA

Related parts for AD7792BRUZ