2-1419130-4 TE Connectivity, 2-1419130-4 Datasheet - Page 468

no-image

2-1419130-4

Manufacturer Part Number
2-1419130-4
Description
Electromechanical Relay SPDT 1A 12VDC 960Ohm Through Hole
Manufacturer
TE Connectivity
Type
Miniature Sealed Relayr
Datasheets

Specifications of 2-1419130-4

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
12.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Coil Resistance
960Ohm
Contact Current Rating
1A
Contact Material
Silver Nickel/Gold Plated
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-1419130-4
Manufacturer:
TE
Quantity:
39 178
Part Number:
2-1419130-4
Manufacturer:
TE/AMP
Quantity:
35 000
1312
Ordering Information
Our authorized distributor is more likely to stock these items.
WD47 Specifications
Nominal Operating Range: 120 to 480 VAC.
Maximum Sensing Range: 575VAC.
Nominal Frequency Range: 40-400 Hz.
Contact Form:
Control Voltage:
WD47-001
WD47 Typical Hookup
WD47 Operation
WD47 phase sequence relays are designed to monitor the correct phase
rotation and loss of phase of three phase ac systems from 50 to 400 Hz. An
incorrect phase sequence or loss of any phase will cause the WD47 to pickup.
When the phase sequence is corrected or the lost phase is restored the
contacts dropout. Red LED's light to indicate a fault condition. A green LED
indicates power to the relay. The WD47 is often used to detect reverse phase
rotation or loss of phase to generators, busses, motors, and transformers.
Model WD47
Input Voltage (VDC)
Input Voltage (VAC)
Dimensions are shown for
reference purposes only.
1. Basic Series:
2. Type:
3. Control Voltage:
WD = DIN mount Protective Relay.
47= Phase Sequence Relay.
001 = 18 to 54VDC
002 = 13.5 to 32 VDC
003 = 100-200VDC or 100-140VAC.
Typical Part Number
2 form C (DPDT).
B
18 to 54
-001
Dimensions are in inches over
(millimeters) unless otherwise
specified.
13.5 to 32
WD
-002
47 -002
100 to 200
100 to 140
-003
Catalog 1308242
Issued 3-03
WD47 Phase Sequence Relays
• Function 47
• ANSI/IEEE C37.90-1978
WD47 Calibration
The WD47 has no adjustments and no calibration is necessary. Proper
operation may be verified as follows:
1.
2.
3.
WD47 Controls
WD47 Connections
Apply a nominal, three-phase input with the correct phase sequence.
The output relay should dropout and the green LED should light.
Apply a nominal, three-phase input with an incorrect phase sequence.
The output relay should pickup and the red LED should light.
Apply only one or two phases with the correct phase sequence. The
output relay should pickup and the red LED should light.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
KILOVAC