2-1419130-4

Manufacturer Part Number
2-1419130-4
Description
Electromechanical Relay SPDT 1A 12VDC 960Ohm Through Hole
Manufacturer
TE Connectivity
Type
Miniature Sealed Relayr
Datasheets

Specifications of 2-1419130-4

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
12.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Coil Resistance
960Ohm
Contact Current Rating
1A
Contact Material
Silver Nickel/Gold Plated
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-1419130-4
Manufacturer:
TE
Quantity:
39 178
Part Number:
2-1419130-4
Manufacturer:
TE/AMP
Quantity:
35 000
Dimensions are shown for
reference purposes only.
WD25 Specifications
Nominal Operating Range: 120, 208, 277 or 480 VAC, selectable.
Maximum Sensing Range: 575VAC.
Nominal Frequency Range: 40-400.
Contact Form:
Sense Voltage:
Control Voltage:
Ordering Information
Our authorized distributor is more likely to stock these items.
WD25-001
WD25-013
WD25 Typical Hookup
NOTE:
For single dead bus option, connect the
generator to 1 & 2 and the bus to 4 & 5.
WD25 Operation
WD25 paralleling relays are used to ensure that two circuits are synchro-
nized. When voltage, phase relationship and frequency are within the se-
lected synchronizing limits, the output relay will energize. The WD25 paral-
leling relay allows for a generator to be brought online without damage or
system disturbance. WD25 series with a "dead bus" feature will energize
for a synchronized condition or an "on line" generator, "dead bus" condition.
This "dead bus" feature allows the generator to energize a dead bus. The
"double dead bus" feature permits paralleling of two buses when: (a) both
the line voltages are equal and in phase, or (b) when either bus is "hot" and
the other bus is "dead."
Voltage (nominal)
Synch Voltage (% of nom.)
Dead Bus Voltage (% of nom.)
Model WD25
Input Voltage (VDC)
Input Voltage (VAC)
Typical Part Number
1. Basic Series:
2. Type:
3. Dead Bus:
4. Control Voltage:
WD = DIN mount Protective Relay.
25 = Paralleling Relay.
00 = Double Dead Bus
01 = Single Dead Bus
02 = Generator to Generator
1 = 18 to 54VDC
2 = 13.5 to 32 VDC
3 = 100-200VDC or 100-140VAC.
2 form C (DPDT).
B
18 to 54
120
6 - 30% ( 4 - 20 electrical degree)
-0X1
Dimensions are in inches over
(millimeters) unless otherwise
specified.
10 - 70% (Dead Bus)
208
WD 25 -00
13.5 to 32
-0X2
277
100 to 200
100 to 140
-0X3
480
2
Catalog 1308242
Issued 3-03
WD25 Calibration
The calibration marks on the faceplate are provided only as guides. Proper
calibration requires using an accurate voltmeter. Use the following proce-
dure to calibrate the WD25:
1. Remove the cover.
2. Adjust the SYNC VOLTAGE control fully counterclockwise (CCW). Apply
3. Apply the maximum desired synchronization voltage to the LINE A (gen-
4. Slowly adjust the SYNC VOLTAGE control clockwise (CW) until the relay
WD25 Controls
WD25 Connections
WD25 Paralleling Relays
• Function 25
• ANSI/IEEE C37.90-1978
nominal voltage to the LINE B (bus) sensing terminals.
erator) terminals. This voltage should be in phase with LINE B (bus) volt-
age and have the same frequency.
energizes.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
KILOVAC
1309

Related parts for 2-1419130-4