Electromechanical Relay SPDT 1A 12VDC 960Ohm Through Hole
Manufacturer
TE Connectivity
Type
Miniature Sealed Relayr
Datasheets

Specifications of 2-1419130-4

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
12.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Coil Resistance
960Ohm
Contact Current Rating
1A
Contact Material
Silver Nickel/Gold Plated
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-1419130-4
Manufacturer:
TE
Quantity:
39 178
Part Number:
2-1419130-4
Manufacturer:
TE/AMP
Quantity:
35 000
Fits 1.77 x 1.77 (45 x 45)
Panel cutout
Dimensions are shown for
reference purposes only.
Timing and Counting Modes
Timing Specifications
Timing Ranges: 0.1 to 99.9 / 1 to 999 sec.; 0.1 to 99.9 / 1 to 999 min.;
Timing Adjustment: Digital adjustment via thumbwheel switches.
Tolerance:
Delta Time (for AC units add 1 cycle 60 Hz.):
Repeatability (Including first cycle of operation.):
Reset Time (power interruption): 45 ms, typ.; 60 ms, max.
Minimum Pulse Width, Control: 50 ms.
Recycle Time: 45 ms, typ.; 60 ms, max.
Counting Specifications
Maximum Count: 1 to 999; 10 to 9,990 ( 10); 100 to 99,900 ( 100).
Maximum Count Rate: 100 counts per second.
Mimumum Pulse Width:Count (Control): 3 ms.; Reset: 3 ms.
Available Counting Functions: Operate at preset count and release at
Contact Data @ 25 C
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Initial Dielectric Strength
Between Open Contacts: 1,000V rms, 60 Hz.
Between All Other Conductors: 1,500V rms, 60Hz.
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
Universal Input Model
Fixed Input Models
Outline Dimensions
See the following page for a complete description of all program-
mable timing and counting modes.
(47 .8)
1.88
120VAC.
24-240VAC/VDC
A
Input Voltage
Input Voltage
1
0.5% 0.05 sec.
120VAC
(47 .8)
12VDC
1.88
1
0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr.
O
1
NC
H
N
preset count.
(8.1)
.32
Dimensions are in inches over
(millimeters) unless otherwise
specified.
(71.9)
2.83
0.1% 0.05 sec.
(80.0)
Part Number
3.15
Part Number
CNT-35-96
CNT-35-26
CNT-35-76
0.1% 0.05 sec.
(16.3)
.64
(44.7)
1.76
Catalog 1308242
Issued 3-03
CNT
Multifunction, Digital
Time Delay Relay/Counter
• 10 programmable timing modes + 2 counting modes
• 0.1 sec. to 9,990 hr. programmable timing range
• 1 to 99,900 counting range
• LCD digital display
• Universal (24-240VAC/VDC) and fixed input types
• 10A output relay with DPDT contacts
• Thumbwheel switches for programming
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25 C
Voltage: Universal Input Type: 24 - 240V 15%, 50/60 Hz. AC or DC.
Power Requirement:
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
Environmental Data
Temperature Range: Storage: -20 C to +70 C.
Humidity: 85% relative humidity, non-condensing.
Mechanical Data
Termination: 11-pin octal style plug.
Enclosure: Beige plastic 1/16 DIN case.
Sockets: Fits either 27E123 or 27E892 (snap-on) screw terminal sockets.
Weight: 4.3 oz. (122g) approximately.
External Control: CONTROL, RESET: Active on contact closure or solid
Accessories
Wiring Diagrams (Bottom Views)
(pins numbered clockwise from keyway)
* Note: Input polarity for DC operation. For most reliable operation on AC, connect high side
** Important: A dry circuit switch is recommended. A “dry circuit” switch is one rated to
Input Voltages & Limits @ 25 C
EXTERNAL CONTROL SWITCHES**
Part Number
SSA-24C667
SSA-24C668 Protective Cover
Universal Input Type: 10VA @ 240VAC; 5VA @ 120VAC; 1VA @ 24VAC.
Fixed Input Types: 3VA @ 120VAC; 3W @ 12VDC.
RETURN
File E22575
File LR15734
Universal
AC models will operate on 50 or 60 Hz.
Specifications and availability
subject to change.
Fixed
Input
+
Type
to “+” and low side to “–”.
Fixed Input Types: 120VAC 15%, 50/60 Hz and 12VDC.
CONTROL
INPUT*
(COUNT)
1 11
reliably switch currents of less than 50mA. Use of a switch rated for other
than dry circuit may result in failure of the time delay relay to function properly.
series
Mounting Clip
state switch closure to RETURN, 0-1.0VDC maximum
voltage level (see wiring diagrams for interface circuits.
Name
_
RESET
24-240VAC/VDC
Operating: -10 C to +55 C.
Nominal
Voltage
10W @ 240VDC; 5W @ 120VDC; 1W @ 24VDC.
120VAC
12VDC
CNT to help protect against dust and moisture.
Clear, flexible cover slips snugly over bezel of
Durable cover also helps prevent inadvertant
Ratchet-fit clip slides onto CNT from behind
to secure CNT in panel mount applications.
changes of programming switch settings.
FOR RESET
USE SAME
20.4VAC/VDC
Minimum
10.2VDC
102VAC
Voltage
Description
CONTROL
RETURN
+
RESET
INPUT*
1
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
11
276VAC/VDC
Maximum
Voltage
_
13.8VDC
138VAC
P&B
1211

Related parts for 2-1419130-4