2-1419130-4 TE Connectivity, 2-1419130-4 Datasheet - Page 360

no-image

2-1419130-4

Manufacturer Part Number
2-1419130-4
Description
Electromechanical Relay SPDT 1A 12VDC 960Ohm Through Hole
Manufacturer
TE Connectivity
Type
Miniature Sealed Relayr
Datasheets

Specifications of 2-1419130-4

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
12.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Coil Resistance
960Ohm
Contact Current Rating
1A
Contact Material
Silver Nickel/Gold Plated
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-1419130-4
Manufacturer:
TE
Quantity:
39 178
Part Number:
2-1419130-4
Manufacturer:
TE/AMP
Quantity:
35 000
1012
Voltage: 12VDC.
Resistance: See Coil Data table.
Nom. Power: See Coil Data table.
Thermal Resistance: 55°C per actual coil watt in still air with no contact
Features
• 20A, 16VDC switching rating.
• 75A inrush at 16VDC.
• 20A continuous contact rating @ 85°C.
• Operation to 105°C ambient.
• Immersion cleanable plastic case with knock-off nib for ventilation.
• Low profile package has a seated height of only .67” (17 mm).
• H-Bridge motor reversing arrangement.
Conditions
All parametric, environmental and life tests are performed according to EIA
Standard RS-407-A at standard test conditions (23°C Ambient, 20-50% RH,
29.5 ± 1.0” Hg.) unless otherwise noted.
Contact Data
Arrangements: 2 x 1 Form C (H-Bridge).
Material: AgNi 0.15 (consult factory for other contact materials).
Max. Switching Rate: 20 operations per second with no contact load.
Max. Switching Voltage: 24VDC.
Max. Load Current 23°C (@ 14VDC Load Voltage):
Max. Switching Power: 320 watts DC (voltage dependent)
Min. Recommended Current: 0.5 amp @ 12VDC.
Initial Voltage Drop: 400 millivolts, maximum (measured between load
Nominal Circuit Resistance: 6 milliohms load terminal to load terminal
Expected Life:
Initial Insulation Resistance @ 500VDC
Between Contacts and Coil: 10 megaohms.
Between Open Contacts: 10 megaohms.
Coil Data
Coil Data (@ 23°C Coil Temperature)
Dimensions are shown for
reference purposes only.
Continuous Carry: 20 Amperes
Intermittent Carry: 40 Amperes for 30 seconds.
Make: 75 Amperes
Break: 40 Amperes
Mechanical: 10 million operations.
Electrical: 20A, 14VDC, 1mH > 100K operations.
V2R-1001
Number
Relay
Part
40A, 14VDC, 0.5mH > 10K operations.
terminals) @ 10 amp contact load.
Rated Coil
load current.
Voltage
6 operations per minute for rated life at rated load.
(VDC)
12
@ 10 amp (this value is provided for circuit
design purposes only and is not a
specified parameter).
±10% (Ohms)
Resistance
Coil
150
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Inductance
(1)
(H) (Ref.)
Coil
0.7
Catalog 1308242
Issued 3-03
Must-Operate
Voltage
(VDC)
6.0
(1) See Figure 1.
(2) See Figure 2.
(3) Current and times are compatable with circuit protection by a typical
(4) Allowable overdrive is rated at ambient temperature of 23°C and
Environmental Data
Temperature Range: Storage: -40°C to +155°C.
Shock: 20g, 11 milliseconds, half sine wave pulse.
Vibration: (For NC contacts, NO contacts are significantly higher.)
Mechanical Data
Termination: Printed circuit terminals.
Enclosure: Immersion cleanable, sealed plastic cover.
Weight: Sealed: 25 gm (0.9 oz.) approximately.
Audible Sound: 95dBA @ 10 cm, 14VDC coil voltage.
Abnormal Operation
Overload Current: 40A, 36 sec.
24V Jump Start: 24VDC for 5 minutes conducting rated contact current
Flammability: UL94V-0 (meets FMVSS 302).
Notes
V2R
20 Amp DC Motor Reversing
PC Board Relay
for Automotive Applications
Operate Data
Must Operate and Must Release Voltage: See Coil Data table.
Initial Operate Time: 5 milliseconds, typical, with rated coil voltage
Initial Release Time: 2 milliseconds, typical, with zero volts applied (for
Drop Test: Capable of meeting specifications after a 1.0 meter drop onto
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Specifications and availability
subject to change.
20A circuit breaker. Relay will make, carry and break the specified
current.
105°C, as stated, with a 10A load current flowing throuth the relay
contacts and minimum coil resistance with power applied for 30 sec.
max. (20% max. duty cycle). For continuous duty information, see
Figure 2 (AmbientTemperature vs. Coil Voltage for Continuous Duty.)
10-40 Hz., 1.27mm double amplitude.
40-70 Hz., 5g's constant.
70-100 Hz., 0.5mm double amplitude.
100-500 Hz., 10g's constant.
Must-Release
concrete in final enclosure.
series
Voltage
(VDC)
0.9
77dBA @ 1 M, 14VDC coil voltage.
@ 23°C.
80A, 10 sec.
150A, 2.5 sec.
Operating: -40°C to +105°C.
unsuppressed relays after having been energized at
rated coil voltage.)
applied.
Nominal
(Watts)
Power
0.93
(3)
TYCO ELECTRONICS
@ 23°C
24V
(2)
Allowable
Overdrive
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
(VDC)
(4)
@ 105°C
16V

Related parts for 2-1419130-4