MC33596FJE Freescale Semiconductor, MC33596FJE Datasheet - Page 24

IC RECEIVER UHF PLL TUNED 32LQFP

MC33596FJE

Manufacturer Part Number
MC33596FJE
Description
IC RECEIVER UHF PLL TUNED 32LQFP
Manufacturer
Freescale Semiconductor
Type
Receiverr
Datasheet

Specifications of MC33596FJE

Frequency
304, 315, 426, 434, 868 & 915MHz
Sensitivity
-104dBm
Data Rate - Maximum
22.4 kBaud
Modulation Or Protocol
FSK, OOK
Applications
General Data Transfer
Current - Receiving
10.3mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Voltage - Supply
2.7 V ~ 3.6 V, 4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
32-LQFP
Operating Frequency
915 MHz
Operating Supply Voltage
3.3 V or 5 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Modulation Type
FSK/OOK
Package Type
LQFP
Operating Supply Voltage (min)
2.7V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC33596FJE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC33596FJER2
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
MC33596FJER2
Quantity:
16 000
Company:
Part Number:
MC33596FJER2
Quantity:
16 000
Receive Mode
11.4.2 Operation
Two modes of operation are available: sample mode and continuous mode.
11.4.2.1 Sample Mode
Sample mode allows the peak power of a specific pulse in an incoming frame to be measured.
The quasi peak detector is reset by closing S1. After 7 × T
is set high. On the falling edge of RSSIC, S2 is opened. The voltage on RSSIOUT is sampled and held.
The last RSSI conversion results are stored in the RSSI register and no further conversion is done.
The RSSI register is updated every 32 × T
RSSIC is 32 × T
11.4.2.2 Continuous Mode
Continuous mode is used to make a peak measurement on an incoming frame, without having to select a
specific pulse to be measured.
The quasi peak detector is reset by closing S1. After 7 × T
is set high. As long as RSSIC is kept high, S2 is closed, and RSSIOUT follows the peak value with a decay
time constant of 5 ms.
The ADC runs continuously, and continually updates the RSSI register. Thus, reading this register gives
the most recent conversion value, prior to the register being read. The minimum duration of the high pulse
on CONFB is 32 × T
24
RSSI Register
RSSIOUT
CONFB
RSSIC
MOSI
MISO
S1
S2
digclk
Frozen
Open
Peak Detector
Closed
digclk
.
Reset
7 x t
.
digclk
Updated
Figure 16. RSSI Operation in Sample Mode
Closed
Open
Sampling
MC33596 Data Sheet, Rev. 4
digclk
. Therefore, the minimum duration of the high pulse on
digclk
CMD
digclk
Sampled and Hold RSSI Voltage
, S1 is released. S2 is closed when RSSIC
, S1 is opened. S2 is closed when RSSIC
RSSI Value
Closed
Frozen
Open
Freescale Semiconductor