C8051F560-IQ Silicon Laboratories Inc, C8051F560-IQ Datasheet - Page 288

IC 8051 MCU 32K FLASH 32-QFP

C8051F560-IQ

Manufacturer Part Number
C8051F560-IQ
Description
IC 8051 MCU 32K FLASH 32-QFP
Manufacturer
Silicon Laboratories Inc
Series
C8051F56xr
Datasheets

Specifications of C8051F560-IQ

Program Memory Type
FLASH
Program Memory Size
32KB (32K x 8)
Package / Case
32-QFP
Core Processor
8051
Core Size
8-Bit
Speed
50MHz
Connectivity
SMBus (2-Wire/I²C), CAN, LIN, SPI, UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
25
Ram Size
2.25K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.25 V
Data Converters
A/D 25x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Processor Series
C8051F5x
Core
8051
Data Bus Width
8 bit
Data Ram Size
2304 B
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
25
Operating Supply Voltage
1.8 V to 5.25 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F560DK
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1691 - KIT DEVELOPMENT FOR C8051F560
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1693

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F560-IQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F560-IQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051F55x/56x/57x
Note that the 8-bit offset held in PCA0CPH5 is compared to the upper byte of the 16-bit PCA counter. This
offset value is the number of PCA0L overflows before a reset. Up to 256 PCA clocks may pass before the
first PCA0L overflow occurs, depending on the value of the PCA0L when the update is performed. The
total offset is then given (in PCA clocks) by Equation 26.5, where PCA0L is the value of the PCA0L register
at the time of the update.
The WDT reset is generated when PCA0L overflows while there is a match between PCA0CPH5 and
PCA0H. Software may force a WDT reset by writing a 1 to the CCF5 flag (PCA0CN.5) while the WDT is
enabled.
26.4.2. Watchdog Timer Usage
To configure the WDT, perform the following tasks:
The PCA clock source and Idle mode select cannot be changed while the WDT is enabled. The watchdog
timer is enabled by setting the WDTE or WDLCK bits in the PCA0MD register. When WDLCK is set, the
WDT cannot be disabled until the next system reset. If WDLCK is not set, the WDT is disabled by clearing
the WDTE bit.
The WDT is enabled following any reset. The PCA0 counter clock defaults to the system clock divided by
12, PCA0L defaults to 0x00, and PCA0CPL5 defaults to 0x00. Using Equation 26.5, this results in a WDT
timeout interval of 256 PCA clock cycles, or 3072 system clock cycles. Table 26.3 lists some example time-
out intervals for typical system clocks.
288
Disable the WDT by writing a 0 to the WDTE bit.
Select the desired PCA clock source (with the CPS[2:0] bits).
Load PCA0CPL5 with the desired WDT update offset value.
Configure the PCA Idle mode (set CIDL if the WDT should be suspended while the CPU is in Idle
mode).
Enable the WDT by setting the WDTE bit to 1.
Reset the WDT timer by writing to PCA0CPH5.
PCA0CPL5
C
D
L
I
W
D
E
T
PCA0MD
W
D
C
K
L
PCA0CPH2
C
P
S
2
Figure 26.11. PCA Module 2 with Watchdog Timer Enabled
Write to
C
P
S
1
C
P
S
0
Equation 26.5. Watchdog Timer Offset in PCA Clocks
C
E
F
Offset
8-bit Adder
=
Enable
Adder
256
x
Enable
PCA0CPL5
Rev. 1.1
PCA0CPH5
Comparator
PCA0H
8-bit
+
256 PCA0L
Match
PCA0L Overflow
Reset

Related parts for C8051F560-IQ