TAJA225K006RNJ AVX Corporation, TAJA225K006RNJ Datasheet - Page 16

CAP TANT 2.2UF 6.3V 10% SMD

TAJA225K006RNJ

Manufacturer Part Number
TAJA225K006RNJ
Description
CAP TANT 2.2UF 6.3V 10% SMD
Manufacturer
AVX Corporation
Series
TAJr
Type
Moldedr
Datasheets

Specifications of TAJA225K006RNJ

Capacitance
2.2µF
Package / Case
1206 (3216 Metric)
Voltage - Rated
6.3V
Tolerance
±10%
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Size / Dimension
0.126" L x 0.063" W (3.20mm x 1.60mm)
Height
0.063" (1.60mm)
Manufacturer Size Code
A
Features
General Purpose
Tolerance (+ Or -)
10%
Voltage
6.3VDC
Esr
9Ohm
Mounting Style
Surface Mount
Polarity
Polar
Construction
SMT Chip
Case Style
Molded
Case Code
A
Lead Spacing (nom)
Not Requiredmm
Df
6%
Dcl
0.5uA
Seal
Not Required
Insulation
Not Required
Failure Rate
Not Required
Wire Form
Not Required
Product Length (mm)
3.2mm
Product Height (mm)
1.6mm
Product Depth (mm)
1.6mm
Product Diameter (mm)
Not Requiredmm
Seated Plane Height
Not Requiredmm
Length W/weld (max)
Not Requiredmm
Operating Temp Range
-55C to 125C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Spacing
-
Esr (equivalent Series Resistance)
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
TAJA225K006R
TAJA225K006R
Technical Summary and
Application Guidelines
3.1 STEADY-STATE
Tantalum Dielectric has essentially no wear out mechanism
and in certain circumstances is capable of limited self
healing. However, random failures can occur in operation.
The failure rate of Tantalum capacitors will decrease with time
and not increase as with other electrolytic capacitors and
other electronic components.
The useful life reliability of the Tantalum capacitor is affected
by three factors. The equation from which the failure rate can
be calculated is:
where FU is a correction factor due to operating
Base failure rate.
Standard tantalum product conforms to Level M reliability
(i.e., 1%/1000 hrs.) at rated voltage, rated temperature,
and 0.1 /volt circuit impedance. This is known as the
base failure rate, FB, which is used for calculating operating
reliability. The effect of varying the operating conditions on
failure rate is shown on this page.
Operating voltage/voltage derating.
If a capacitor with a higher voltage rating than the maximum
line voltage is used, then the operating reliability will be
improved. This is known as voltage derating.
The graph, Figure 2a, shows the relationship between volt-
age derating (the ratio between applied and rated voltage)
and the failure rate. The graph gives the correction factor FU
for any operating voltage.
44
SECTION 3
RELIABILITY AND CALCULATION OF FAILURE RATE
F = FU x FT x FR x FB
voltage/voltage derating
FT is a correction factor due to operating
temperature
FR is a correction factor due to circuit series
resistance
FB is the basic failure rate level. For standard
Tantalum product this is 1%/1000 hours
Useful life reliability can be altered by voltage
derating, temperature or series resistance
Infant
Mortalities
Figure 1. Tantalum Reliability Curve
Infinite Useful Life
Figure 2b. Gives our recommendation for voltage derating
Figure 2a. Correction factor to failure rate F for voltage
0.0010
1.0000
0.1000
0.0100
0.0001
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
Figure 2c. Gives voltage derating recommendations
40
30
20
10
0.01
derating of a typical component (60% con. level).
0
0
0
4 6.3 10
0.1
as a function of circuit impedance.
to be used in typical applications.
0.1
0.2
Applied Voltage / Rated Voltage
Circuit Resistance (Ohm/V)
0.3
1.0
16 20
Rated Voltage (V)
Recommended Range
0.4
0.5
10
25
0.6
Low Impedance Circuit
100
0.7
Specified Range in
35
in General Circuit
Specified Range
0.8
1000
0.9
10000
1
50