LD4T06P0 Red Lion Controls, LD4T06P0 Datasheet - Page 3

TIMER 6 DIGIT 4.0" 120VAC RED

LD4T06P0

Manufacturer Part Number
LD4T06P0
Description
TIMER 6 DIGIT 4.0" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Timerr
Datasheets

Specifications of LD4T06P0

No. Of Digits / Alpha
6
Digit Height
101mm
Power Consumption
26VA
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
4"
Ip/nema Rating
IP65 / NEMA 4X
Signal Output Type
Relay
Accuracy
±0.01% %
Connection Type
Wire Leads
Dimensions
26"L×2.25"W×7.875"H
Display Digit Height
4 "
Display Resolution
0.001 Sec. (Minimum Digit), 1 hr. (Single Digit)
Display Type
LED
Function
Timer
Material, Casing
Aluminum
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0 to 999999
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Supply Voltage Range
21.6V DC To 250V DC
Count Speed Max
10Hz
External Depth
57.15mm
External Length / Height
200mm
Rohs Compliant
Yes
Counter Supply Voltage
85-250VAC/11-16VDC
Display Font Color
Red
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
RLC125
EMC INSTALLATION GUIDELINES
Magnetic Interference (EMI), proper installation and wiring methods must be
followed to ensure compatibility in each application. The type of the electrical
noise, source or coupling method into the meter may be different for various
installations. The meter becomes more immune to EMI with fewer I/O
connections. Cable length, routing, and shield termination are very important
and can mean the difference between a successful or troublesome installation.
Listed below are some EMC guidelines for successful installation in an
industrial environment.
1. The meter should be properly connected to protective earth.
2. Use shielded (screened) cables for all Signal and Control inputs. The shield
3. Never run Signal or Control cables in the same conduit or raceway with AC
To access the switches, remove the right side plate of the meter. A bank of eight
switches is located inside the unit. Note: Some switches are not used and should
SWITCH 1 (Unused)
SWITCH 2 (Input A) {See Note 1}
SWITCH 3 (Input A)
SWITCH 4 (Input B) {See Note 1}
SWITCH 5 (Input B)
2.0 S
3.0 W
Although this meter is designed with a high degree of immunity to Electro-
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in order
of their effectiveness.
a. Connect the shield only at the panel where the unit is mounted to earth
b. Connect the shield to earth ground at both ends of the cable, usually when
c. Connect the shield to common of the meter and leave the other end of the
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be ran in metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
remain in the factory set position.
This switch is not used and should remain in the factory set position.
SNK: Adds internal 7.8 K pull-up resistor to +12 VDC, I
SRC: Adds internal 3.9 K pull-down resistor, 7.2 mA max. @ 28 VDC max.
FILTER ON: Provides hardware debounce for Input A to allow relay or
SNK: Adds internal 7.8 K pull-up resistor to +12 VDC, I
SRC: Adds internal 3.9 K pull-down resistor, 7.2 mA max. @ 28 VDC max.
FILTER ON: Provides hardware debounce for Input B to allow relay or
ground (protective earth).
the noise source frequency is above 1 MHz.
shield unconnected and insulated from earth ground.
switch contacts to be used as a signal source. Software debounce for Inputs
A and B is provided in the programming menu (Module 1).
switch contacts to be used as a signal source. Software debounce for Inputs
A and B is provided in the programming menu (Module 1).
Warning: Exposed line voltage exists on the circuit boards.
Remove all power to the meter and load circuits before accessing
inside of the meter.
ETTING THE
IRING THE
M
DIP S
MAX
MAX
ETER
= 2.1 mA.
= 2.1 mA.
WITCHES
3
SWITCH 6 (RESET/USER INPUT) {See Note 1}
SWITCH 7 (Unused)
SWITCH 8 (Input B)
Note 1: When the DIP switch is in the SNK position (OFF), the input is
4. Signal or Control cables within an enclosure should be routed as far as possible
5. In extremely high EMI environments, the use of external EMI suppression
6. Long cable runs are more susceptible to EMI pickup than short cable runs.
7. Switching of inductive loads produces high EMI. Use of snubbers across
SNK: Adds internal 7.8 K pull-up resistor to +12VDC, I
SRC: Adds internal 3.9 K pull-down resistor, 7.2 mA max. @ 28 VDC max.
This switch is not used and should remain in the factory set position.
NORMAL: Input B performs the normal functions described in the Timer
INTENSITY ADJUST: In this position, Input B is used to adjust the LED
configured as active low. When the switch is in the SRC position (ON), the
input is configured as active high.
from contactors, control relays, transformers, and other noisy components.
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional protection.
Install line filters on the power input cable to the unit to suppress power line
interference. Install them near the power entry point of the enclosure. The
following EMI suppression devices (or equivalent) are recommended:
Note: Reference manufacturer's instructions when installing a line filter.
Therefore, keep cable runs as short as possible.
inductive loads suppresses EMI.
Snubber: RLC# SNUB0000.
Input Operation parameter of the programming menu (Module 1).
display intensity. Five distinct LED levels can be set by pulsing Input B.
The display intensity level can also be set in the programming menu
(Module 3).
Ferrite Suppression Cores for signal and control cables:
Line Filters for input power cables:
Fair-Rite # 0443167251 (RLC# FCOR0000)
TDK # ZCAT3035-1330A
Steward # 28B2029-0A0
Schaffner # FN610-1/07 (RLC# LFIL0000)
Schaffner # FN670-1.8/07
Corcom # 1 VR3
Input A
Input B
Reset/User Input SNK
Input B Normal
FILTER OFF
FILTER OFF
UNUSED
UNUSED
SNK
SNK
8
5
6
1
2
3
4
7
Factory Setting
ON
SRC
ON
SRC
ON
SRC
Intensity Adjust
MAX
= 2.1 mA.

Related parts for LD4T06P0