EVAL-ADT7467EBZ ON Semiconductor, EVAL-ADT7467EBZ Datasheet - Page 55

no-image

EVAL-ADT7467EBZ

Manufacturer Part Number
EVAL-ADT7467EBZ
Description
BOARD EVALUATION FOR ADT7467
Manufacturer
ON Semiconductor
Series
dBCool®r
Datasheet

Specifications of EVAL-ADT7467EBZ

Sensor Type
Temperature
Sensing Range
-40°C ~ 120°C
Interface
SMBus (2-Wire/I²C)
Sensitivity
±1.5°C
Voltage - Supply
3 V ~ 5.5 V
Embedded
No
Utilized Ic / Part
ADT7467
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
putting the ADT7467 into manual mode and changing the
PWM output from 0% to 100% PWM duty cycle. The PWM
output takes 35 sec to reach 100% when a ramp rate of 1 time
slot is selected.
Figure 76 shows remote temperature plotted against PWM duty
cycle for enhanced acoustics mode. The ramp rate is set to 48,
which corresponds to the fastest ramp rate. Assume that a new
temperature reading is available every 115 ms. With these
settings, it takes approximately 0.76 sec to go from 33% duty
cycle to 100% duty cycle (full speed). Even though the
temperature increases very rapidly, the fan ramps up to full
speed gradually.
Figure 77 shows how a ramp rate of 8 affects the control loop.
The overall response of the fan is slower than it is with a ramp
rate of 48. Because the ramp rate is reduced, it takes longer for
the fan to achieve full running speed. In this case, it takes
approximately 4.4 sec for the fan to reach full speed.
140
120
100
120
100
80
60
40
20
80
60
40
20
0
0
0
0
Figure 76. Enhanced Acoustics Mode with Ramp Rate = 48
Figure 77. Enhanced Acoustics Mode with Ramp Rate = 8
R
R
TEMP
TEMP
(°C)
(°C)
PWM DUTY CYCLE (%)
TIME (s)
TIME (s)
PWM DUTY CYCLE (%)
4.4
Rev. 3 | Page 55 of 77 | www.onsemi.com
0.76
120
100
80
60
40
20
0
140
120
100
80
60
40
20
0
Figure 78 shows the PWM output response for a ramp rate of 2.
With these conditions, the fan takes about 17.6 sec to reach full
running speed.
Figure 79 shows how the control loop reacts to temperature
with the slowest ramp rate. The ramp rate is set to 1; all other
control parameters are the same as they are for Figure 76
through Figure 78. With the slowest ramp rate selected, it takes
35 sec for the fan to reach full speed.
As Figure 76 to Figure 79 show, the rate at which the fan reacts
to a temperature change is dependent on the ramp rate selected
in the enhanced acoustics registers. The higher the ramp rate,
the faster the fan reaches the newly calculated fan speed.
140
120
100
120
100
80
60
40
20
80
60
40
20
0
0
0
0
Figure 78. Enhanced Acoustics Mode with Ramp Rate = 2
Figure 79. Enhanced Acoustics Mode with Ramp Rate = 1
R
TEMP
R
TEMP
(°C)
(°C)
TIME (s)
TIME (s)
PWM DUTY CYCLE (%)
PWM DUTY CYCLE (%)
17.6
ADT7467
35
140
120
100
80
60
40
20
0
120
100
80
60
40
20
0

Related parts for EVAL-ADT7467EBZ