R0E0200F0EMU00 Renesas Electronics America, R0E0200F0EMU00 Datasheet - Page 298

no-image

R0E0200F0EMU00

Manufacturer Part Number
R0E0200F0EMU00
Description
EMULATOR E200 MAIN BODY-SH7780
Manufacturer
Renesas Electronics America
Series
SuperH®r
Type
In-Circuit Emulatorr
Datasheet

Specifications of R0E0200F0EMU00

Contents
Emulator Board, Cables, Software and Documentation
For Use With/related Products
SH7780
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
272
⎯ There is a restriction when the tail call is used to call another function from the function
(ii) Nesting functions
(iii) Calling from a function outside the measurement range
that has been called by the tail call. If the tail call occurs continuously, three-step
measurement will be correctly performed.
If 32-step or more calls are generated from the top function within the range to be
measured, correct measurement will not be performed. A warning message will be
displayed.
Correct measurement will not be performed if a function outside the measurement range
calls a function to be measured and the callee function cannot return correctly to the caller
function.
Even if the callee function returns correctly to the caller function, correct measurement will
not be performed if other functions are called within three instructions from the return
address.
The user program execution starts from a function outside the measurement range and then
moves to a function within the measurement range. After that, the execution branches to
another function outside the measurement range.
f( ){
g( );
Figure 5.98 Restriction on Call
}
g( ){
h( );
}
Step 1
h( ){
k( );
}
Step 2
k( ){
}
Step 3