HS38000EPI61H Renesas Electronics America, HS38000EPI61H Datasheet - Page 93

no-image

HS38000EPI61H

Manufacturer Part Number
HS38000EPI61H
Description
DEV EMULATOR BASE UNIT H8/38000
Manufacturer
Renesas Electronics America
Type
Microcontrollerr
Datasheet

Specifications of HS38000EPI61H

Contents
E6000 Emulator and CD-ROM
For Use With/related Products
38000 Series
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5.7.8
The trigger point is an event to output a trigger when the specified address has been accessed. Up to four trigger
points can be set by using the trigger outputs (four channels) on the bus monitoring circuit of the emulator.
The settings of the trigger point are displayed and modified on the [Trigger] sheet.
Selecting [Add...] or the event point and [Edit...] from the popup menu in this window displays the [Set Address
For Trigger] dialog box.
This dialog box allows the user to specify the address to be accessed as the trigger output condition during the
user program execution. Enable or disable the trigger output point by checking the check box on the left in the
screen.
[Trigger1]:
[Trigger2]:
[Trigger3]:
[Trigger4]:
[Address]:
72
Setting Trigger Points
Enables the output of trigger channel 1.
Enables the output of trigger channel 2.
Enables the output of trigger channel 3.
Enables the output of trigger channel 4.
Sets the address condition of the channel.
Figure 5.28 [Set Address For Trigger] Dialog Box
Figure 5.27 [Event] Window ([Trigger] Sheet)