101-1108 Rabbit Semiconductor, 101-1108 Datasheet - Page 22

KIT EMBEDDED PLC APPLICATION

101-1108

Manufacturer Part Number
101-1108
Description
KIT EMBEDDED PLC APPLICATION
Manufacturer
Rabbit Semiconductor
Series
Coyoter
Type
MPU Moduler
Datasheet

Specifications of 101-1108

Contents
BL2500, ISaGRAF V3.50, Embedded PLC software kernel, ISaGRAF Programming Cable and Documentation
Processor To Be Evaluated
Rabbit 3000
Interface Type
RS-232, Ethernet
For Use With/related Products
BL2500
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
316-1120
EMBEDDED
2. Double-click on the sample application (for example, rfdemo) to open the Programs Manager
3. On the Programs Manager window, select Debug → Simulate (or press Simulate button
4. The I/O simulation window shows the I/O boards used by the application (Boards 0 to 4). Board 0
5. To close the simulation of the application, close the Debugger window. Close the Programs window.
6. Try with other sample applications such as the one listed in the introduction of this chapter. All the
OEM Technology Solutions
window.
the toolbar). The Debugger, I/O simulation and Debug program windows are displayed.
(column 0) has 8 digital inputs; Board 1 (column 1) has 8 analog inputs; Board 2 (column 2) has 8
message (strings) outputs; Board 3 (column 3) has 8 digital outputs and Board 4 (column 4) has 8
analog outputs. On Board 0 (column 0) click on Input 1 and Input 4, a message start and Lead are
displayed in message outputs 4 and 5 respectively; and Board 3 will show the LED outputs being
turned ON in sequence. On the Debug programs window the Drive and Lead programs change to
active state. Unset the digital input 4 and set any of the digital inputs 5 (Flash) or 6 (Random).
sample applications can run in simulation mode.
PLC BL2500 User’s Manual
Running Sample Applications
Page 16
on

Related parts for 101-1108