RDK-138 Power Integrations, RDK-138 Datasheet - Page 2

KIT REF DESIGN 1.2W PS TN FAMILY

RDK-138

Manufacturer Part Number
RDK-138
Description
KIT REF DESIGN 1.2W PS TN FAMILY
Manufacturer
Power Integrations
Datasheets

Specifications of RDK-138

Mfg Application Notes
LinkSwitch-TN Design Guide, AN-37
Main Purpose
AC/DC, Non-Isolated
Outputs And Type
2, Non-Isolated
Power - Output
1.2W
Voltage - Output
12V, 5V
Current - Output
80mA, 50mA
Voltage - Input
85 ~ 265VAC
Regulator Topology
Buck
Frequency - Switching
66kHz
Board Type
Fully Populated
Utilized Ic / Part
LNK304
Product
Accessories & Kits
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
596-1197
Table of Contents
1
2
3
4
5
6
7
8
9
10
11
12
Important Note:
Although this board is designed to satisfy safety isolation requirements, the engineering
prototype has not been agency approved. Therefore, all testing should be performed
using an isolation transformer to provide the AC input to the prototype board.
4.1
4.2
4.3
4.4
4.5
7.1
7.2
7.3
9.1
9.2
9.3
9.4
9.5
Introduction.................................................................................................................3
Power Supply Specification ........................................................................................4
Schematic...................................................................................................................5
Circuit Description ......................................................................................................6
PCB Layout ................................................................................................................9
Bill of Materials .........................................................................................................10
Performance Data ....................................................................................................11
7.1.1
7.3.1
7.3.2
Thermal Performance...............................................................................................16
Waveforms ...............................................................................................................17
9.5.1
9.5.2
Conducted EMI .....................................................................................................23
Line Surge.............................................................................................................24
Revision History ....................................................................................................25
AC Input Rectification and EMI Filtering ..............................................................6
LinkSwitch-TN Device .........................................................................................6
Output Rectification and Filtering ........................................................................7
Feedback Network ..............................................................................................7
Linear Regulator..................................................................................................8
Efficiency ...........................................................................................................11
No-load Input Power..........................................................................................13
Regulation .........................................................................................................13
Drain Voltage and Current, Normal Operation...................................................17
Output Voltage Start-up Profile..........................................................................17
Source Voltage and Drain Current Start-up Profile............................................18
Load Transient Response (75% to 100% Load Step) .......................................19
Output Ripple Measurements............................................................................21
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Active Mode CEC Measurement Data........................................................11
Load and Line ............................................................................................13
Line ............................................................................................................15
Ripple Measurement Technique ................................................................21
Measurement Results ................................................................................22
Page 2 of 28

Related parts for RDK-138