7.4
7.4.1
Detection voltage level
VDCR2<VDxEN>
VDCR1<VDxSF>
VDCR1<VDxF>
Setting of register
Figure 7-3 Change of voltage detection flag and voltage detection status flag
causes the VDCR1<VDxF> flag to be set. This flag remains set until it is cleared by software. VDCR1<VDxF>
is not cleared to 0 when the supply voltage (VDD) becomes equal to or higher than the detection voltage
(VDxLVL).
VDCR1<VDxF> can only be cleared by writing a 0.
causes the VDCR1<VDxSF> flag to be set to 1. When VDD rises above VDxLVL, the VDCR1<VDxSF> flag
is cleared to 0.
cording to the relation between VDD and VDxLVL.
voltage condition.
Setting Procedure for Generate an interrupt
VDD level
When VDCR2<VDxEN>=1, a drop of the supply voltage (VDD) below the threshold voltage (VDxLVL)
Once VDCR1<VDxF> has been set to 1, this state is retained even if VDCR2<VDxEN> is cleared to 0.
When VDCR2<VDxEN>=1, a drop of the supply voltage (VDD) below the threshold voltage (VDxLVL) also
Unlike the VDCR1<VDxF> flag, the VDCR1<VDxSF> flag does not remain set and changes its state ac-
The following shows the setting procedure for generating an INTVLTD interrupt upon detection of a low-
Note:Depending on the voltage detect timing, the voltage detect status flag (VDCR1<VDxSF>) may be set
Note:If the selected threshold voltage (VDxLVL) is close to the supply voltage (VDD), INTVLTD interrupts may
1. Clear the INTVLTD interrupt enable flag <EF4> to 0.
2. Select the threshold voltage by programming the VDCR1<VDxLVL> (x=1, 2) bits.
3. Clear the VDCR2<VDxMOD> bit to 0 to generate an INTVLTD interrupt upon detection of a low-
4. Set the VDCR2<VDxEN> bit to 1 to enable voltage detect operation.
5. Wait for 5 us until the voltage detecting circuit stabilizes.
6. Ensure that the VDCR1<VDxSF> is 0.
7. Clear VDCR1<VDxF> to 0.
8. Clear the INTVLTD interrupt latch <IL4> to 0 and set the interrupt enable flag <EF4> to 1 to enable
one machine cycle before the voltage detect flag (VDCR1<VDxF>) is set.
voltage condition.
interrupts.
be generated frequently. After returning from the low-voltage detect interrupt routine, insert wait pro-
cessing as appropriate with consideration given to transitions in the system supply voltage before clearing
the interrupt latch.
VDCR2 because of "0" the flag is not set