LZSA-1000-3 TDK Corporation, LZSA-1000-3 Datasheet - Page 6

PWR SUP 24V 1008W 42A

LZSA-1000-3

Manufacturer Part Number
LZSA-1000-3
Description
PWR SUP 24V 1008W 42A
Manufacturer
TDK Corporation
Series
LZSAr
Type
Industrialr
Datasheets

Specifications of LZSA-1000-3

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
1000W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 42 A
Size / Dimension
10.5" L x 5.62" W x 4.75" H (266.7mm x 142.7mm x 120.7mm)
Power (watts) - Rated
1008W
Operating Temperature
-40°C ~ 71°C
Efficiency
84%
Approvals
CE, EN, UL
Line Regulation
0.1%
Load Regulation
0.1%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
42A
Power Rating
1008W
Input Voltage
85V AC To 265V AC / 100V DC To 400V DC
Brand/series
LZSA Series
Configuration
Enclosed
Operation
Linear
Output
24 VDC @ 42 A
Power, Output
1008 W
Primary Type
AC-DC
Special Features
High Reliability, Parallelable, Remote Adjust, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/100 to 400 VAC/VDC
Voltage, Output
24 VDC
Input Frequency
47 to 440Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
71C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1455
LZSA10003

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LZSA-1000-3
Manufacturer:
TDK
Quantity:
100
LZS-A A 1000-3 3 Power Supply
Page. 4
Revision H : December 2009
This manual is a description of specifications, features and applications of LZS-A1000 power supplies.
RATINGS AND SPECIFICATIONS *
*
** Output current and power, as measured at output terminals, must be less than or equal to
*** Regulatory agency compliance applies only for operating frequencies between 47-63Hz.
Input Voltage Range***
Input Current (RMS, maximum)
Inrush Current (Peak, at cold start)
Power Factor Harmonics
Power Factor (at max output power)
Input Power (maximum)
Input Surge Protection
Input EMI Conducted Emissions
Efficiency (at max.output power)
Maximum Ratings
Input Specifications
Output Performance Specifications
Output Voltage Range
Output Current (Power) @ 60°C**
DC Output @ 24V
Output Current (Power) @ 70°C**
Operating Temperature
Start-up Temperature
Voltage Line Regulation
Voltage Load Regulation
Ripple and Noise @ 20 MHz
measurement Bandwidth.
Temperature Coefficient
Startup Time (at 110 VAC input)
Overshoot
Holdup Time (Full Power/220VAC)
Ride through (Full Power/220VAC)
Voltage Sag Immunity
(Full Power/110VAC)
Load Transient Response
(25% step load change)
Refer to figures 1-7 for supply-load connection information.
quoted maximum values for a given ambient temperature.
No safety agency approvals for 100-380 VDC operation. Minimum turn-ON voltage for
DC Input is 110 VDC, unit will operate as low as 65 VDC after Power-up. Lambda doesn’t
recommend operation below 100 VDC for more than one minute, or damage may occur.
(PARD-mVP-P)
Units
A(W)
A(W)
Units
VDC
VAC
Units
%/°C
°C
°C
W
Sec.
V
A
A
%
mV
mS
mS
-
-
-
-
%
%
-
-
47-63Hz 100% rated load from -30°C to 60°C derate
Over 63Hz to 440Hz 100% rated load from -30°C
to 55°C derate linearly to 60% @ 65°C (4%/°C)
1kV Differential Mode; 2kV common mode
1214W @ 42A (1008W) and 85VAC line
No overshoot at turn on or turn off
+/-1% of Vo ; 1A /µS; Recovers to within
85-265 (47-440Hz) Single Phase
FCC Class B, CISPR 22 Class B
linearly to 60% @ 70°C (4%/°C)
30A /110VAC; 40A / 220VAC
83 typical @ 110VAC line
EN61000-3-2 Compliant
0.99 typical @ 85VAC
+/-0.2% in < 1.25 mS
Semi-F47 compliant
Less than 1 second
LZS-A1000-3
LZS-A1000-3
LZS-A1000-3
-40° to +70°
25.2 (605)
42 (1008)
100-380
20 RMS
18-29.4
.01
0.1
0.1
75
10
20
Table 2
Table 3
Table 4

Related parts for LZSA-1000-3