LZSA-1000-3 TDK Corporation, LZSA-1000-3 Datasheet - Page 5

PWR SUP 24V 1008W 42A

LZSA-1000-3

Manufacturer Part Number
LZSA-1000-3
Description
PWR SUP 24V 1008W 42A
Manufacturer
TDK Corporation
Series
LZSAr
Type
Industrialr
Datasheets

Specifications of LZSA-1000-3

Power Supply Type
Switching (Closed Frame)
Voltage - Output
24V
Number Of Outputs
1
Power (watts)
1000W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 42 A
Size / Dimension
10.5" L x 5.62" W x 4.75" H (266.7mm x 142.7mm x 120.7mm)
Power (watts) - Rated
1008W
Operating Temperature
-40°C ~ 71°C
Efficiency
84%
Approvals
CE, EN, UL
Line Regulation
0.1%
Load Regulation
0.1%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
24V
Output Current
42A
Power Rating
1008W
Input Voltage
85V AC To 265V AC / 100V DC To 400V DC
Brand/series
LZSA Series
Configuration
Enclosed
Operation
Linear
Output
24 VDC @ 42 A
Power, Output
1008 W
Primary Type
AC-DC
Special Features
High Reliability, Parallelable, Remote Adjust, Remote On/Off, Remote Sense
Voltage, Input
85 to 265/100 to 400 VAC/VDC
Voltage, Output
24 VDC
Input Frequency
47 to 440Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
71C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1455
LZSA10003

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LZSA-1000-3
Manufacturer:
TDK
Quantity:
100
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
Emissions
AC Line Conducted Emissions
Radiated RF Emissions
Powerline Harmonics
Powerline Fluctuation/Flicker
Immunity
Electrostatic Discharge
RF Radiated Fields
Electrical Fast Transients
Lightning Surge
Conducted RF Common Mode
Power Frequency Magnetic Field
Voltage Dips/Short Variations
Additional Immunity
Ring Wave Lightning Surge Test
EN55022/EN55011
EN55022/EN55011
EN61000-3-2
EN61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
SEMI-F47 (100 VAC)
IEEE C62.41
(0.15-30 MHz) Class B
30-1000 MHz Class B
Class A Limits
Complies
+/-8 kV Air
+/-6 kV Contact
10 V/m, 80 MHz-2.5GHz
80% AM @ 1kHZ
+/-2 kV AC Line, Criteria A
+/-1 kV I/O Line > 3m, Criteria A
+/-2 kV line to GND (CM), Criteria A
+/-1 kV line to line (DM), Criteria A
10 V/m RMS, 150 kHz-80 MHz
80% AM at 1kHz
3 A/m
5% of nom. line for .5 cycles - Criteria A
40% for 5 cycles - Criteria A
70% for 25 cycles - Criteria A
95% Dip for 5 seconds -
Unit should not latch
50% of nom. line for 200 msec
70% for 500 msec
80% for 10 seconds
90% for 15 seconds
0% for 1 cycle or 20mS
6 kV/30 Ohm Criteria A
LZS-A A 1000-3 3 Power Supply
Revision H : December 2009
Table 1
Page. 3

Related parts for LZSA-1000-3