DS1874T+ Maxim Integrated Products, DS1874T+ Datasheet - Page 75

IC CTLR SFP+ ANLG LDD 28-TQFN

DS1874T+

Manufacturer Part Number
DS1874T+
Description
IC CTLR SFP+ ANLG LDD 28-TQFN
Manufacturer
Maxim Integrated Products
Type
Laser Diode Controllerr
Datasheet

Specifications of DS1874T+

Number Of Channels
1
Voltage - Supply
2.85 V ~ 3.9 V
Current - Supply
2.5mA
Operating Temperature
-40°C ~ 95°C
Package / Case
28-WFQFN Exposed Pad
Mounting Type
Surface Mount
Number Of Outputs
5
Duty Cycle (max)
50 %
Output Voltage
0 V to 3.9 V
Mounting Style
SMD/SMT
Switching Frequency
0 KHz to 400 KHz
Operating Supply Voltage
2.85 V to 3.9 V
Supply Current
2.5 mA to 10 mA
Maximum Operating Temperature
+ 95 C
Fall Time
300 ns
Minimum Operating Temperature
- 40 C
Rise Time
300 ns
Synchronous Pin
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
90-1874T+000
Table 02h, Register C7h: TBLSELPON
Table 02h, Register C8h–C9h: MAN BIAS
Table 02h, Register CAh: MAN_CNTL
CAh
C7h
C8h
C9h
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE
Chooses the initial value for the table-select byte (Lower Memory, Register 7Fh) at power-on.
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE
When BIAS EN (Table 02h, Register 80h) is written to 0, writes to these bytes control the BIAS register, which then
updates the MAX3798/MAX3799 SET_IBIAS register.
When BIAS EN (Table 02h, Register 80h) is written to 0, MAN_CLK controls the updates of the MAN BIAS value to
the BIAS register. This new value is sent through the 3-wire interface. The values of MAN BIAS must be written with
a separate write command. Setting MAN_CLK to a 1 clocks the MAN BIAS value to the BIAS register, which then
updates the MAX3798/MAX3799 SET_IBIAS register.
1) Write the MAN BIAS value with a write command.
2) Set the MAN_CLK bit to a 1 with a separate write command.
3) Clear the MAN_CLK bit to a 0 with a separate write command.
RESERVED
SFP+ Controller with Digital LDD Interface
BIT 7
BIT 7
BIT 7
2
2
0
7
7
______________________________________________________________________________________
RESERVED
2
2
0
6
6
00h
PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
(PW2 and BIAS EN = 0) or (PW1 and RWTBL246 and BIAS EN = 0)
Volatile
00h
PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
PW2 or (PW1 and RWTBL246)
Nonvolatile (SEE)
0000h
PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)
(PW2 and BIAS EN = 0) or (PW1 and RWTBL246 and BIAS EN = 0)
Volatile
RESERVED
2
2
0
5
5
RESERVED
2
2
0
4
4
RESERVED
2
2
0
3
3
RESERVED
2
2
0
2
2
RESERVED
2
2
0
1
1
MAN_CLK
BIT 0
BIT 0
BIT 0
2
2
2
8
0