ADP1048DC1-EVALZ Analog Devices, ADP1048DC1-EVALZ Datasheet - Page 81

no-image

ADP1048DC1-EVALZ

Manufacturer Part Number
ADP1048DC1-EVALZ
Description
Daughter Cards & OEM Boards ADP1048 DAUGHTERCARD
Manufacturer
Analog Devices
Series
ADP1048r
Datasheet

Specifications of ADP1048DC1-EVALZ

Rohs
yes
Product
Daughter Cards
Description/function
100 kHz daughter board
Dimensions
40 mm x 25 mm
Interface Type
I2C
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
3.3 V
Factory Pack Quantity
1
For Use With
ADP1048
Data Sheet
IBAL CONFIGURATION REGISTER
Table 160. Register 0xFE95—IBAL Configuration
Bits
7
6
[5:4]
3
[2:0]
DEBUG FLAG REGISTERS
Table 161. Register 0xFE96—Debug Flag 0
Bits
7
6
5
4
3
2
1
0
Table 162. Register 0xFE97—Debug Flag 1
Bits
7
6
5
4
3
2
1
0
Table 163. Register 0xFE98—Debug Flag 2
Bits
7
6
5
4
3
2
1
0
Bit Name
IBAL disconnect
IBAL at load transient
RSVD
IBAL at low power
mode
RSVD
Bit Name
OT_WARN
OT_FAULT
TEMPERATURE
UNKNOWN
MFR_FAULT
PSON
PGOOD
AC_OK
Bit Name
EEPROM_UNLOCKED
EEPROM_CRC
I2C_ADDRESS
FAST_LOOP
MAX_MODULATION
MIN_MODULATION
SOFT_START
SYNC_LOCK
Bit Name
VIN_UV
VIN_LOW
VIN_UV_FAULT
VIN_UV_WARN
LOW_LINE
BROWN_OUT
CML
VDD_3.3V_OV
R/W
R/W
R/W
R
R/W
R
R/W
R
R
R
R
R
R
R
R
R/W
R
R
R
R
R
R
R
R
R/W
R
R
R
R
R
R
R
R
(ADP1048
Description
1 = disconnect the output of the current balance block from the PWM outputs.
0 = connect the output of the current balance block to the PWM outputs.
0 = disable current balancing when the fast loop is triggered.
1 = enable current balancing when the fast loop is triggered.
It is recommended that this bit be set to 0.
Reserved.
1 = disable current balancing under low power mode if the output of the current balancing
block reaches the limit.
0 = enable current balancing under low power mode even if the output of the current
balancing block reaches the limit.
It is recommended that this bit be set to 1.
Reserved.
Description
1 = EEPROM is unlocked and its contents can be written.
1 = downloaded EEPROM contents are incorrect.
1 = fast loop compensation filter is in use.
1 = maximum modulation limit is reached.
1 = minimum modulation limit is reached.
1 = system is in soft start sequence; fast loop filter is in use.
Description
1 = general input undervoltage fault (same as Register 0x7C, Bit 4).
1 = VAC is lower than VIN_OFF (Register 0x36). This signal shuts down the power supply.
1 = input voltage on VAC is smaller than the value in VIN_UV_FAULT_LIMIT (Register 0x59).
1 = input voltage on VAC is smaller than the value in VIN_UV_WARN_LIMIT (Register 0x58).
1 = input voltage is higher than the high line threshold.
1 = VAC is lower than the value stored in VIN_ON (Register 0x35).
1 = communications, memory, or logic fault.
1 = an overvoltage condition is present on the VDD rail.
Description
1 = measured temperature is above the value of OT_WARN_LIMIT.
1 = measured temperature is above the value of OT_FAULT_LIMIT.
1 = temperature fault or warning.
1 = fault or warning not listed in Register 0x79, Bits[15:1].
1 = manufacturer-specific fault or warning (Register 0xFE80, Register 0xFE81, Register 0xFE82).
1 = PSON signal (hardware or software) is inactive.
Power good. This flag is a programmable combination of other internal flags and refers to the
condition of the output voltage. A value of 1 means that the output of the PGOOD pin is low.
This flag is a programmable combination of other internal flags and refers to the condition of
the input voltage. A value of 1 means that the output of the AC_OK pin is low.
1 = the resistor on the ADD pin has a value that can cause an error in the address assignment
(the address falls too close to the threshold between two addresses).
1 = external synchronization frequency is locked.
(ADP1048
ONLY)
Rev. 0 | Page 81 of 84
Only)
ADP1047/ADP1048

Related parts for ADP1048DC1-EVALZ