M24LR16E-RDW6T/2 STMicroelectronics, M24LR16E-RDW6T/2 Datasheet - Page 25

no-image

M24LR16E-RDW6T/2

Manufacturer Part Number
M24LR16E-RDW6T/2
Description
EEPROM 16kB EEPROM Dual INT 400 kHz IC2 13.56MHz
Manufacturer
STMicroelectronics
Datasheet

Specifications of M24LR16E-RDW6T/2

Product Category
EEPROM
Rohs
yes
Memory Size
16 Kbit
Organization
256 x 8
Data Retention
40 yr
Maximum Clock Frequency
400 KHz
Maximum Operating Current
50 mA
Operating Supply Voltage
1.8 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-8
Access Time
900 ns
Interface Type
2-Wire Serial, I2C
Minimum Operating Temperature
-40 C
Operating Current
50 mA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24LR16E-RDW6T/2
Manufacturer:
ST
0
Company:
Part Number:
M24LR16E-RDW6T/2
Quantity:
4 000
M24LR16E-R
The next two bits of the Sector security status byte (b
The value of these two bits is used to link a password to the sector, as defined in
Table 9.
The M24LR16E-R password protection is organized around a dedicated set of commands,
plus a system area of three password blocks where the password values are stored. This
system area is described in
Table 10.
The dedicated commands for protection in RF mode are:
Add
1
2
3
Write-sector password:
The Write-sector password command is used to write a 32-bit block into the password
system area. This command must be used to update password values. After the write
cycle, the new password value is automatically activated. It is possible to modify a
password value after issuing a valid Present-sector password command. On delivery,
the three default password values are set to 0000 0000h and are activated.
Lock-sector:
The Lock-sector command is used to set the sector security status byte of the selected
sector. Bits b
command. The sector lock bit, b
command, the protection settings of the selected sector are activated. The protection of
a locked block cannot be changed in RF mode. A Lock-sector command sent to a
locked sector returns an error code.
b
4
00
01
10
11
, b
3
Password control bits
Password system area
4
to b
1
of the sector security status byte are affected by the Lock-sector
Table
Doc ID 018932 Rev 8
10.
The sector is not protected by a password.
0
The sector is protected by password 1.
The sector is protected by password 2.
The sector is protected by password 3.
, is set to 1 automatically. After issuing a Lock-sector
Password 1
Password 2
Password 3
Password
3
, b
4
) are the password control bits.
System memory area
Table
25/143
9.